Habasit Italiana S.p.A.
Via del Lavoro 50
I-31016
– Cordignano (TV)
Tel.: +39 0438 9113
Fax: +39 0438 912374
Use and maintenance manual
W-01
Author:
FT
Page 10 of 15
Edition:
06/2017
R. 0
Replaces:
6 Welding of round belts
Procedure: refer to the user manual of the CQ positioning device used.
7 Maintenance
Always keep the welding device clean. Clean the heating plate [1] regularly and remove all material residues.
Clean the heating plate [1] while heated with a cotton cloth
For cleaning with a cloth moistened with water or solvent, the welder must be
disconnected from the power supply.
Do not reconnect to the power supply until the welder is completely dry.
Burning hazard! Fold cotton cloth in several layers to assure good insulation!. Do not
touch hot surfaces
Never clean heating plate [1] with hard objects (such as screwdrivers, spatulas etc.)!
This will damage the Teflon coating
Periodically inspect the power supply cable and connector plug for defects (insulation damage, etc.) and
rectify or replace with the correct type where necessary.
7.1 Measuring of the plate temperature on the welder W-01/6 or W-01/8
Check the operating temperature of the welding device once a month.
Carry out this check in an interior room in a draft-free environment with an ambient temperature of between
18 °C / 64 °F and 25 °C / 77 °F.
Heat up the welder for at least 10 minutes.
Insert a precision temperature probe into the hole [2] of the
heating plate [1].
The temperature gauge ought to indicate 270 °C ± 10 °C / 519
°F ± 18 °F and it must be comparable (± 5 °C / ± 9,5 °F) with
the value shown on the display of the welder.
Should the measured temperature deviates from 270 °C ± 10
°C / 519 °F ± 18 °F, adjust with a screwdriver, increasing or
decreasing gradually, the set temperature. When you generate
a rotation of the adjustment spindle of the temperature set, the
display shows the “flashing” value of the current temperature
set. After each change of the set, leave for a few minutes to
stabilize the platen temperature on the new value and then
check the real value of the plate temperature on the display and
on the measuring thermometer. In case of failure to reach the
temperature value, replace the welder.
Summary of Contents for PQ-02
Page 20: ......