10-28
LED
Error code
Faulty item
•
Cb
—DIMM in slot A11
•
CC
—DIMM in slot A12
d1 through d9,
dA, db, or dC
DIMM slots for processor 4:
•
d1 through d9
—DIMMs in slots B1 through B9
•
dA
—DIMM in slot B10
•
db
—DIMM in slot B11
•
dC
—DIMM in slot B12
HDD
00 through 07
Drives in slots 0 through 7 in bay 1
08 through 15
Drives in slots 0 through 7 in bay 2
16 through 23
Drives in slots 0 through 7 in bay 3
32 and 33
•
32
—Drive in slot 9 at the rear
•
33
—Drive in slot 9 at the rear
PCIE
00
Embedded Ethernet adapter
01 through 10
PCIe modules in PCIe slots 1 to 10 of a riser card
NOTE:
If a storage controller is installed in a PCIe slot, the RAID LED
displays the storage controller status.
11
sLOM Ethernet adapter
PSU
01 Power
supply
1
02 Power
supply
2
FAN
01 through 06
Fan 1 through Fan 6
VRD
01
P5V_STBY voltage on the system board
02
P3V3_STBY voltage on the system board
03
P1V05_PCH_STBY voltage on the system board
04
PVNN_PCH_STBY voltage on the system board
05
P1V8_PCH_STBY voltage on the system board
06
P5V voltage on the system board
07
P3V3 voltage on the system board
60
PVCCIO_CPU1 voltage on the system board
61
PVCCIN_CPU1 voltage on the system board
62
PVCCSA_CPU1 voltage on the system board
63
VDDQ_CPU1_ABC voltage on the system board
64
VDDQ_CPU1_DEF voltage on the system board
65 VPP_CPU1_ABC
voltage on the system board
66
VPP_CPU1_DEF voltage on the system board
67
VTT_CPU1_ABC voltage on the system board
68
VTT_CPU1_DEF voltage on the system board
69
P1V0_CPU1 voltage on the system board
6A
PVMCP_CPU2 voltage on the system board