![H3C S5120-SI Series Operation Manual Download Page 535](http://html2.mh-extra.com/html/h3c/s5120-si-series/s5120-si-series_operation-manual_3711174535.webp)
1-17
Figure 1-8
Network diagram for NTP symmetric peers mode configuration
Configuration procedure
1) Configuration on Device B:
# Specify Device A as the NTP server of Device B.
<DeviceB> system-view
[DeviceB] ntp-service unicast-server 3.0.1.31
2) View the NTP status of Device B after clock synchronization.
[DeviceB] display ntp-service status
Clock status: synchronized
Clock stratum: 3
Reference clock ID: 3.0.1.31
Nominal frequency: 100.0000 Hz
Actual frequency: 100.0000 Hz
Clock precision: 2^18
Clock offset: -21.1982 ms
Root delay: 15.00 ms
Root dispersion: 775.15 ms
Peer dispersion: 34.29 ms
Reference time: 15:22:47.083 UTC Sep 19 2005 (C6D95647.153F7CED)
As shown above, Device B has been synchronized to Device A, and the clock stratum level of Device B
is 3, while that of Device C is 1.
3) Configuration on Device C (after Device B is synchronized to Device A):
# Configure Device B as a symmetric peer after local synchronization.
[DeviceC] ntp-service unicast-peer 3.0.1.32
In the step above, Device B and Device C are configured as symmetric peers, with Device C in the
symmetric-active mode and Device B in the symmetric-passive mode. Because the stratus level of
Device C is 1 while that of Device B is 3, Device C is synchronized to Device B.
# View the NTP status of Device B after clock synchronization.
[DeviceB] display ntp-service status
Clock status: synchronized
Clock stratum: 4
Reference clock ID: 3.0.1.32
Nominal frequency: 100.0000 Hz