1-2 

Temperature and humidity 

Maintain the temperature and humidity in the equipment room as described in 

Table1-2

. 

 

High temperature can accelerate the aging of insulation materials and significantly lower the 
reliability and lifespan of the device. 

 

Lasting high relative humidity can cause poor insulation, electricity leakage, mechanical 
property change of materials, and metal corrosion. 

 

Lasting low relative humidity can cause washer contraction and ESD and bring issues 
including loose screws and circuit failure. 

Table1-2 Temperature and humidity requirements 

Temperature 

Humidity 

 

Operating: 0°C to 45°C (32°F to 113°F) 

 

Storage: –40°C to +70°C (–40°F to +158°F) 

5% RH to 95% RH, noncondensing 

 

Cleanliness 

Dust buildup on the chassis might result in electrostatic adsorption, which causes poor contact of 
metal components and contact points, especially when indoor relative humidity is low. In the worst 
case, electrostatic adsorption can cause communication failure. 

Table1-3 Dust concentration limit in the equipment room 

Substance 

Concentration limit (particles/m

3

Dust particles 

≤ 3 x 10

4

 

(No visible dust on the tabletop in three days) 

NOTE: 

Dust diameter ≥ 5 µm 

 

The equipment room must also meet limits on salts, acids, and sulfides to eliminate corrosion and 
premature aging of components, as shown in 

Table1-4

. 

Table1-4 Harmful gas limits in an equipment room 

Gas 

Maximum concentration (mg/m

3

SO

2

 

0.2 

H

2

0.006 

NH

3

 

0.05 

NO

2

 

0.04 

Cl

2

 

0.01 

 

Cooling system 

The ICG2000D, ICG2000H, and ICG 2000H-DC use passive cooling. The ICG2000D-EI uses left-
to-right airflow for heat dissipation, as shown i

Figure1-1

. 

For adequate cooling of the device, make sure the following requirements are met: 

 

A minimum clearance of 100 mm (3.94 in) is reserved around the air inlet and outlet vents. 

Summary of Contents for ICG2000

Page 1: ...H3C ICG2000 Information Communication Gateways Installation Guide New H3C Technologies Co Ltd http www h3c com Document version 6W100 20220817...

Page 2: ...espective owners Notice The information in this document is subject to change without notice All contents in this document including statements information and recommendations are believed to be accur...

Page 3: ...ou replace with actual values Square brackets enclose syntax choices keywords or arguments that are optional x y Braces enclose a set of required syntax choices separated by vertical bars from which y...

Page 4: ...s Convention Description Represents a generic network device such as a router switch or firewall Represents a routing capable device such as a router or Layer 3 switch Represents a generic switch such...

Page 5: ...ardware model configuration or software version It is normal that the port numbers sample output screenshots and other information in the examples differ from what you have on your device Documentatio...

Page 6: ...a rack 2 3 Grounding the device 2 6 Installing SICs 2 7 Connecting interface cables 2 7 Logging in from the console port and setting terminal parameters 2 9 Connecting the power cord 2 10 Verifying t...

Page 7: ...eneral safety recommendations Keep the device and installation tools away from walk areas Place the device in a dry and flat location and make sure anti slip measures are in place Remove all external...

Page 8: ...poor contact of metal components and contact points especially when indoor relative humidity is low In the worst case electrostatic adsorption can cause communication failure Table1 3 Dust concentrat...

Page 9: ...circuit board upward or put it in an antistatic bag Touch only the edges instead of electronic components on the circuit board when you observe or move a removed interface module Attaching an ESD wris...

Page 10: ...htning strikes route interface cables only indoors Lightning protection To enhance lightning protection for the device follow these guidelines Make sure the grounding cable of the chassis is connected...

Page 11: ...40 C to 70 C 40 F to 158 F Humidity 5 RH to 95 RH noncondensing Cleanliness Dust concentration 3 10 4 particles m 3 no visible dust on the Flathead screwdriver Phillips screwdriver Needle nose pliers...

Page 12: ...ional Port lightning protectors are available Optional Power lightning protectors are available Optional Signal cable lightning protectors are available Electricity safety A UPS is available The power...

Page 13: ...hassis cover intact and if you want to open the chassis contact H3C for permission Otherwise H3C shall not be liable for any consequence Installation prerequisites You have read Preparing for installa...

Page 14: ...es Connect the device to the configuration terminal Connect the power cord Verify the installation Power on the device Troubleshoot the device Power off the device Operating correctly End Mount the de...

Page 15: ...ubber feet to the four round holes in the chassis bottom 2 Place the device upside up on the workbench Make sure the rubber feet stand securely on the workbench Figure2 2 Mounting the device on a work...

Page 16: ...recommended A minimum of 80 mm 3 15 in between the front rack posts and the front door A minimum of 360 mm 14 17 in between the front rack posts and the rear door Installing the device in a rack CAUT...

Page 17: ...another ear into the same hole Figure2 4 Installing cage nuts 3 Attach mounting brackets to the two sides of the device Figure2 5 Attaching mounting brackets to the device 4 Use M6 screws to attach t...

Page 18: ...end of the grounding cable Attach the hook to the grounding post and use the hex nut to secure the hook to the post Figure2 7 Connecting the grounding cable to the device Grounding the device with a g...

Page 19: ...2 8 Installing a SIC Connecting interface cables Connect cables to the interfaces on the device before powering on the device This section describes the procedure for connecting Ethernet cables For in...

Page 20: ...e bend radius of an optical fiber must be not less than 100 mm 3 94 in Keep the fiber end clean Make sure the Tx and Rx ports on a transceiver module are connected to the Rx and Tx ports on the peer e...

Page 21: ...To disconnect a PC from an operating device first disconnect the device end To connect the console cable 1 Select a configuration terminal which can be an ASCII terminal with an RS 232 serial port or...

Page 22: ...00D EI and ICG 2000H use an AC power cord NOTE The power cord in the following figure is for illustration only To connect the AC power cord 1 Make sure the device is reliably grounded 2 Connect one en...

Page 23: ...als on a power source Insert the DC wire yellow marked into the negative terminal Insert the DC wire red marked into the positive terminal Verifying the installation Verify the following items before...

Page 24: ...le2 2 Table2 2 LED states when the device is operating correctly LED State Description PWR Steady green The power system is operating correctly SYS Slowly flashing green The device system is operating...

Page 25: ...Image file flash icg2000d cmw710 boot e0615p03 bin is self decompressing Done System image is starting Line aux0 is available Press ENTER to get started Press Enter The device is ready to configure w...

Page 26: ...ure see Installing SICs If you are not to install a new SIC install a filler panel in the slot and fasten the screws on the filler panel Replacing a transceiver module 1 Remove the optical fibers from...

Page 27: ...off the device 2 Verify that the device is connected to the power source correctly 3 Verify that the power source is operating correctly 4 Verify that the power cord is in good condition 5 If the issu...

Page 28: ...ation terminal No boot information is displayed on the configuration terminal when the device starts up or restarts up Solution To resolve the issue 1 Verify that the serial console cable is in good c...

Page 29: ...configuration is very complicated and it is hard to locate the errors Solution If you have not saved the configuration you can press the reset button for a short time to reboot the device or power cyc...

Reviews: