2-10
Setting configuration terminal parameters
To configure and manage the device through the console port, you must run a terminal emulator
program, TeraTermPro or PuTTY, on your PC. You can use the emulator program to connect a
network device, a Telnet site, or an SSH site. For more information about the terminal emulator
programs, see the user guides for these programs.
The following are the required terminal settings:
•
Baud rate
—9600.
•
Data bits
—8.
•
Stop bits
—1.
•
Parity
—none.
•
Flow control
—none.
Connecting the power cord
Connecting the AC power cord
The ICG2000D, ICG2000D-EI, and ICG 2000H use an AC power cord.
NOTE:
The power cord in the following figure is for illustration only.
To connect the AC power cord:
1.
Make sure the device is reliably grounded.
2.
Connect one end of the power cord to the AC power receptacle on the device. Use a
releasable cable tie to secure the power cord in place.
3.
Connect the other end of the power cord to an AC power source.
Figure2-12 Connecting the AC power cord
Connecting the DC power cord
Only the ICG2000H-DC uses the DC power cord.
No DC power cord but only a terminal block is provided with the ICG2000H-DC. You must
purchase a DC power cord yourself.
To connect the DC power cord:
1.
Make sure the device is reliably grounded.
2.
Strip off 5 mm (0.20 in) of insulation from one end of the DC wires.