Operation Manual – HWPing
H3C S3100 Series Ethernet Switches
Chapter 1 HWPing Configuration
1-28
[Sysname-hwping-administrator-http] display hwping history administrator
http
HWPing entry(admin administrator, tag http) history record:
Index Response Status LastRC Time
1 13 1 0 2000-04-02 15:15:52.5
2 9 1 0 2000-04-02 15:15:52.5
3 3 1 0 2000-04-02 15:15:52.5
4 3 1 0 2000-04-02 15:15:52.5
5 3 1 0 2000-04-02 15:15:52.5
6 2 1 0 2000-04-02 15:15:52.4
7 3 1 0 2000-04-02 15:15:52.4
8 3 1 0 2000-04-02 15:15:52.4
9 2 1 0 2000-04-02 15:15:52.4
10 2 1 0 2000-04-02 15:15:52.4
For detailed output description, see the corresponding command manual.
Note:
When you use H3C S3100-EI Series Switches as HWPing Client for
http
test, if
configuring the destination address as the host name, you must configure the IP
address of the DNS server to resolve the host name into an IP address, which is the
destination IP address of this HTTP test.
1.3.5 Jitter Test
I. Network requirements
Both the HWPing client and the HWPing server are H3C S3100 series Ethernet
switches. Perform a HWPing jitter test between the two switches to test the delay jitter
of the UDP packets exchanged between this end (HWPing client) and the specified
destination end (HWPing server), with the port number set to 9000.
II. Network diagram
Figure 1-6
Network diagram for the Jitter test