Operation Manual – HWPing
H3C S3100 Series Ethernet Switches
Chapter 1 HWPing Configuration
1-17
Operation
Command
Description
Configure the test type
test-type
{
udpprivate
|
udppublic
}
Required
By default, the test type is
ICMP.
Configure the destination
address
destination-ip
ip-address
Required
This IP address and the
one configured on the
HWPing server for
listening service must be
the same.
By default, no destination
address is configured.
Configure the destination
port
destination-port
port-number
z
Required in a
Udpprivate test
z
A Udppublic test is a
UDP connection test
on port 7. Use the
hwping-server
udpecho ip-address 7
command on the
server to configure the
listening service port;
otherwise the test will
fail. No port number
needs to be configured
on the client; any
destination port
number configured on
the client will not take
effect.
z
By default, no
destination port
number is configured.
Configure the source IP
address
source-ip
ip-address
Optional
By default, no source IP
address is configured.
Configure the source port
source-port port-number
Optional
By default, no source port
is specified.
Configure the number of
probes per test
count
times
Optional
By default, one probe is
made per test.
Configure the maximum
number of history records
that can be saved
history-records
number
Optional
By default, the maximum
number is 50.
Configure the data packet
size
datasize
size
Optional
By default, the data
packet size is 100 bytes.