Integrator Reset Enable
Integrator Reset Enable
Along with the power supply monitoring feature of this amplifier, an integrator reset feature
is provided. Jumper SW EN enables / disables resetting of the integrator of the amplifier.
With this jumper in the 1-2 position, the integrator used for the current feedback loop is
cleared or reset to zero when the amplifier is first powered up, or when the amplifier is
disabled. In the 2-3 position, this feature is disabled.
The factory default configuration is
with the jumper in the 1-2 position, enabling the integrator reset feature
.
Amplifier Configuration Block
The amplifier configuration block allows customization of the amplifier to the user's needs.
These customizable features include:
•
gain setting
•
amplifier tuning
These features allow the user to customize the amplifier to suit a specific application.
Table 2 provides a description of the components used in the configuration block and the
functions that they serve. Figure 6 shows the schematic details of how the components
operate in the configuration of the amplifier.
Power Amplifier Module User's Guide
15
Figure 4. Integrator reset jumper detail.
Integrator Reset
Enable Jumper