MAINTENANCE  

 

Refer all servicing to qualified personnel. 

 

Disconnect the generator and wait until the ventilator stopped before working on the unit. Inside the device, 
voltages and current are dangerous. 

 

Two or three times a year, remove the steel cover and blow off the dust with compressed air. Let check the 
electrical connections (with an insulated tool) and the insulations by qualified personnel. 

 

Regularly  control  the  state  of  the  cord.  If  this  supply  cable  is  damaged,  it  must  be  replaced  by  the 
manufacturer, its after sales service or a similarly qualified technician to avoid any danger. 

 

ADVICE  

 

Respect welding polarities and currents indicated on the electrode packaging 

 

Remove the electrode from the electrode holder when you do not use it. 

 

Leave the inlets free to allow in/out air circulation. 

SECURITY 

The arc welding can be dangerous and leads serious injury, may fatal. Protect yourself and protect the 

others. 

Respect the following warnings: 

 

 
Arc rays 

Protect yourself thanks to a welding helmet in compliance with EN175 equiped with filters in 
compliance with EN 169 or EN 379. Inform and protect by the same means any people in the 
welding environment.

 

Rain, steam, 
humidity 

The working environment must be clean (degree of pollution ≤ 3) and protected against 
rain. Put the appliance on an even place and at least at one meter from the parts to be 
welded. Do not use them under rain or snow.

 

Electric shocks 

This appliance may only be use with a 230V monophase supply and must be earthed.

 

Moving 

Do not underestimate the weight of the apparatus. Do not carry it over people or things. Do 
not drop it. Do not set it brutally

 

Burns 

Wear protective or fire-proof clothing (overalls, jeans). 
Use some welder gloves and a fire-proof apron. 

Protect the others by installing non flammable protection wall , or prevent the others to not 
look at the arc and to keep a sufficient distance

 

Fire risks 

Suppress all flammable products from the working area. Do not works near flammable gas.

 

Smokes 

Do not inhale gas or welding smokes. If indoors ventilate the area well and/or use local 
extraction ventilation equipment to remove fumes and gases.

 

Extraprecautions 

Any welding operation :  
- in environments with increased risk of electric shock, 
- in confined spaces, 
- in the presence of flammable or explosive materials must be evaluated in advance by an 
“Expert supervisor” and must always be carried out in the presence of other people trained 
to intervene in case of emergency. 

Technical protection measures MUST BE taken as described in the TECHNICAL 
SPECIFICATION "IEC 62081". 

Welding in raised positions is forbidden unless safety platforms are used.

 

 

 

 

 

The persons carrying pacemaker have to consult a doctor before using this machine 

Do not use the unit to thaw tubing. 

In TIG welding, manipulate the gas bottle carefully. Indeed, there are risks if the bottle or the bottle 

valve are damaged. 

 

Summary of Contents for GYSMI 220P

Page 1: ...73502_V1_02102012 P 1 3 P 4 6 P 7 9...

Page 2: ...16 CEE 7 7 230 50 60 I1eff 220P 32 0 EN61000 3 11 Zmax 220P Zmax 0 25 Ohms CEI 61000 3 12 MMA 2 5 3 Hot start Arc force Anti sticking EN60974 1 X 60974 1 40 C 10 220P I max 20 200 A 60 10 140 A 100 1...

Page 3: ...2 12 EN 169 EN 379 3 1 CEI IEC 62081 TIG...

Page 4: ...3 12 a b c d e f g h i a b c d A...

Page 5: ...locations due to conducted as well as radiated disturbances This machine is in accordance with the standard EN61000 3 11 if the maximum permissible system impedance Zmax at the interface point of the...

Page 6: ...from the parts to be welded Do not use them under rain or snow Electric shocks This appliance may only be use with a 230V monophase supply and must be earthed Moving Do not underestimate the weight o...

Page 7: ...uctions If interference occurs additional precautions suchas filtering of the mains supply may be required The supply cable in the welding machine s permanent installations may have to be screened in...

Page 8: ...tension Il peut y avoir des difficult s potentielles pour assurer la compatibilit lectromagn tique dans ces sites cause de perturbations conduites aussi bien que rayonn es Ce mat riel est conforme l...

Page 9: ...fils avec neutre reli la terre Ne pas toucher les pi ces sous tension V rifier que le r seau d alimentation est adapt au poste Chutes Ne pas faire transiter le poste au dessus de personnes ou d objet...

Page 10: ...u del des limites des entreprises Recommandation sur les m thodes de r duction des missions lectro magn tiques a Alimentation principale Le poste de soudage devra tre reli au r seau d alimentation con...

Page 11: ...EN 50445 de 2008 EN 60974 10 de 2007 Le marquage CE a t appos en 2012 01 10 12 Nicolas BOUYGUES Soci t GYS Pr sident Directeur G n ral 134 BD des Loges 53941 Saint Berthevin SCHEMA ELECTRIQUE CIRCUIT...

Page 12: ...tages in corresponding load U2 Tensions conventionnelles en charges correspondantes Ventilated Ventill The device complies with European Directive Appareil conforme aux directives europ ennes Conform...

Reviews: