Translation of the original instructions
11
GYSPACK PRO 700 / 900
EN
BATTERY REPLACEMENT
Product
Battery
Type
Voltage (V)
Capacity (Ah)
Dimensions
(cm)
Battery ref
GYSPACK PRO 700
G16EP
Lead acid battery
12
16
18 x 8 x 17
53131
GYSPACK PRO 900
PC950
Lead acid battery
12
30
25 x 9,7 x 15,6
53135
To replace the battery:
• The booster must be disconnected from the power supply.
• Then, unscrew the back panel (picture 1 1 - 8 screw) and remove it.
• The battery is stabilized in the GYSPACK by a battery holder. Loosen the 2 screws located on the front wall so that
the battery can be removed (illustration 2 ) .
• Once this has been done, the front of the battery is visible (see picture). The battery is connected to the GYSPACK
at two points: at the - terminal (picture 3 ) and at the + terminal (picture 4 ). To remove the battery, remove the
2 nuts that enable the connection between the battery and the GYSPACK at the + and - terminals.
When putting a new battery in, make sure to match the polarities of both the battery and the
GYSPACK PRO 700/900. - Terminal on the left, + terminal on the right (see picture). Put the 2
screws and washers back on, tighten the nuts (recommended tightening torque of 4 Nm).
• Tighten again the partition and screw the back panel back on.