12
GYSPACK PRO
EN
Translation of the original instructions
Estimated autonomy of GYSPACK PRO as a 12 V DC power supply
Device
Estimated consumption (in watts)
Estimated automomy (in hours)
Fluorescent cellular light
4
50
Radio, Fan, Echoprobe
9
22
Videocamera, light spot
15
13
Power tool, drying pump
24
8
Air Compressor, Car vaccum cleaner
80
2
SPOT-LIGHT
The GYSPACK PRO has an in-built spotlight comprised of 7 high intensity LEDs controlled by the «light» button.
Repair should always be carried out by qualified personnel.
TROUBLESHOOTING
Troubleshooting
Causes
Solutions
The device beeps.
The device detects a polarity reversal. Check the battery polarity.
Sparks appear when the clampsmake
contact with the battery terminals.
The switch is on position «ON».
Switcht machine off before connec-
ting the clamps to the battery.
The position of the negative and pos-
itive clamps on the battery terminals
is incorrect (polarity reversal).
Check the battery polarity.
The unit can not start the vehicle.
The switch is in the OFF position.
Set the switch to the ON position.
The unit can not start the vehicle. One
of the red or orange LED on the unit
switches on in "test" mode.
The internal battery is discharged.
Charge the unit, and try again after
the charge is complete.
Several jump start attempts without
pause between each.
Wait 3 minutes between 2 starts. A
start must not last more than 6 sec-
onds.
The battery voltage is incorrect..
Check that the battery voltage of the
vehicle is 12V.
The device can not start the vehicle
anymore and no one LED of the de-
vice switches on in "Test" mode.
The voltage of the internal batteries is
very low. It may be that the internal
batteries are damaged.
Put the device on charge in order to
attempt to recover the battery.
The internal batterie is damaged and
it cannot be recharged.
Contact the GYS after sale service to
replace the batterie.
The charge of the internal battery
does not start (none of the charging
LEDs activate).
The external charger plug is not
connected correctly to the socket of
the machine.
Check that the plug is connected cor-
rectly to the machine.
After a day of charge, the end of
charge indicator does not activate.
The internal batteries are damaged
and cannot be recharged.
Contact the GYS after sale service to
organise a replacement of the batte-
ries.
In external 12V power source mode,
the booster no longer delivers power.
The internal thermal protection cir-
cuit-breaker has cut the circuit.
Disconnect the external device
connected to the machine and wait
for the circuit-breaker to reset itself
automatically.
The lamp does not switch on.
The internal battery is discharged.
Charge the unit, and try again after
the charge is complete.