Error messages
PR1713 Operating manual
Seite 52
9.2 Error messages on the text display
These error messages are generated by the current application.
Display
Signification/cause
Dbase error
Opening or writing a table in the database was not possible. The table
is reserved by another program, or not existing.
Tabelle is empty
No table contents were found.
Name already exist
An attempt to insert a new item with a name which already exists in
this table into the database was made. The names in a table must be
different.
Comp. used in rec.
An attempt to delete a component which is used in a recipe was ma-
de. Therefore, the component must be removed from the recipe pre-
viously.
Start error: ##
Error during batch start, ##=error number.
1: recipe table cannot be opened
2: unknown recipe
3: recipe line table cannot be opened
4: no recipe lines existing
5: material table cannot be opened
6: no material existing
7: unknown batch mode
8: internal error
9: no function module of this name existing
10: recipe lines are not numbered continuously
11: invalid PLC bit address
12: no function module existing
13: faulty function module type
14: parameter error in the function module
15: no free memory space
16: parameter error in the function module
17: invalid weighing point name
18: analog section not installed
19: simulation error
20: weighing point cannot be reserved
21: weighing point in error condition
22-29: internal
30: production table cannot be opened
31: production table cannot be written
32: a recipe is already running
33,34: internal
35: no free memory space
36: no licence for a production
37: negative set-point
38: too many active weighing points in the recipe
39: invalid weighing point
40: weighing point parameter in the request component is invalid
41: invalid batch mode for the reactor
42: no memory for the text parameter (recipe line, material)
43: invalid production line number
recipe not starting
Start timeout
The recipe controller was unable to handle the recipe.
no batch licence
PR1713/20 or /21
Batching licence PR1713/20 or PR1713/21 is required for handling
this function.
Analog test failed
Analog test could not be activated. Weighingpoint is not free or in
error.
Summary of Contents for PR 1713/00
Page 5: ...PR1713 Operating manual Operating concept Page 3...
Page 14: ...Operating concept PR1713 Operating manual Seite 12...
Page 16: ...Operating concept PR1713 Operating manual Seite 14...
Page 18: ...Operating concept PR1713 Operating manual Seite 16...
Page 20: ...Operating concept PR1713 Operating manual Seite 18...
Page 50: ...Batching PR1713 Operating manual Seite 48...