GWT PR 1713/00 Operating Manual Download Page 51

PR1713 Operating manual

Setup

Page 49

8 S

ETUP

Various functions can be selected during setup:

Calibration

Configuration

Serial interfaces

Display of board number

Licence number management

Initialization data print-out

Set time

Refresh display

Reboot

These functions are described in the 

)

Installation manual .

Menu item 'Config' permits adjustment of the parameters for
all operating functions.

Setup

!

!

Config            

!

!

Summary of Contents for PR 1713/00

Page 1: ...Release 1 x Other Manuals for PR1713 Installation manual 9499 053 43010 Release 1 0 System manual 9499 054 43110 Release 1 x general Batching manual 9499 057 43210 Release 1 x Programming 9499 053 354...

Page 2: ...kopiert werden Wichtig Die Bedienung des Produktes darf nur von geschultem fach und sachkundigem Personal durchgef hrt werden Durch die Benutzung dieses Produktes werden oben genannte Bestimmungen an...

Page 3: ...4 FIXTARE 15 5 COUNTING SCALE 17 6 BATCHING 19 6 1 INPUT MENU FOR COMPONENT EDITING 20 6 1 1 Editing 20 6 1 2 Component parameters 23 6 1 2 1 Batch Mode 23 6 1 2 2 SPM output address 27 6 1 2 3 SPM i...

Page 4: ...EPORT 40 6 4 1 Consumption 40 6 4 2 Production report 41 6 4 3 Last batch report 42 6 5 ADDRESS LAYOUT OF SIGNALS 43 6 5 1 Digital in and outputmodules PR1713 12 43 6 5 2 SPM addresses for addressing...

Page 5: ...PR1713 Operating manual Operating concept Page 3...

Page 6: ...2 Instrument description The PR1713 basic configuration is an indicator with gross net or tare weight display taring fix tare tables zero setting weight ticket printing checkweighing remote display fu...

Page 7: ...ng point a PR1720 can be connected to the DIOs card Due to programmability licence PR1750 10 writing individual applications or matching the exi sting ones is easy Program package Filtering and contro...

Page 8: ...OF CONTROLS 2 1 Display Weight display status symbols Standstill Gross or net zero within 1 4d G or B Gross weight display dependent of national language NET Net weight display Batching is active bli...

Page 9: ...0 weight f s d unit is not in error status Gross weight is set to zero Conditi on is weight standstill within zero set range not tared batching is not active Menu control keys Softkey for menu select...

Page 10: ...the right side DEF 3 ABC 2 1 MNO 6 JKL 5 GHI 4 WXYZ 9 TUV 8 PQRS 7 del AE 0 enter F3 F2 Stop p B T Tin out 0 P F1 more quit Weight display Alpha numeric display 2 20 Status All functions shall be acce...

Page 11: ...re displayed at a time Selecting a function via softkeys is displayed by two small triangles between the inscription text fields If more than three functions can be selected double tri angles are disp...

Page 12: ...is need being entered or until the number of possible remaining selections is sufficiently low By entry of alphanumeric characters selection from the list is limited and marked by display of a cursor...

Page 13: ...table via the editor Therefore values such as 555 can be entered only by pressing the key successively three times and without using the arrow key A decimal point can be entered with the comma key If...

Page 14: ...Operating concept PR1713 Operating manual Seite 12...

Page 15: ...d tare value Count P Counting application Prod P Batch functions Atest P Start test mode of internal weighingpoint xxx P Other customer applications are appended to the list in this position Setup Con...

Page 16: ...Operating concept PR1713 Operating manual Seite 14...

Page 17: ...rrent gross weight can be loaded and printed out in the fixed tare memory Pressing softkey tare tares the scale with the fixtare value The display returns to the main menu Softkey edit can be used for...

Page 18: ...Operating concept PR1713 Operating manual Seite 16...

Page 19: ...played or printed out By pressing softkey set a new factor is calibrated 1 Discharge the hopper empty bin or plattform and set to zero or tare 2 Calibrate with a selected number of objects and enter...

Page 20: ...Operating concept PR1713 Operating manual Seite 18...

Page 21: ...tion only functions Batch start and Report are required In rare cases the component and recipe tables are edited usually by another person Key more switches between the two softkey menus Softkey Expla...

Page 22: ...editing function Name Preset 125 kg Select component name Select parameter Edit parameter value select component Name Name Preset 100 kg Quit Quit store yes no abc Parameter value remains unchanged ab...

Page 23: ...mponent A number of specific parameters which shall be read out and changed as simply and quickly as pos sible The parameter set changes dependent of the batch mode Component name Batch mode A1 2 B1 B...

Page 24: ...s could be selected by entering alphanumerical keys The setpoint of the calming time is a time which has to be entered with the units ms s m or h Eg 1m30s are one minute and thirty seconds An entry ca...

Page 25: ...normal batch compo nent for charge batching Dossing is prece ded by a tare step i e the net weight is zero when starting the batch The recipe set point for this component is the net weight Charge batc...

Page 26: ...e Subsequently the sy stem waits until the calming time has elapsed to discharge all rests if possible There is no fine flow 6 1 2 1 2 Manual components A manual component D1 is batched manually by a...

Page 27: ...1 4 RW RQ RL RW Wait RL Release RQ Request are used in the recipe for production line synchronization Assuming a weighing point WX shared resource for several production lines RW If WX shall not be st...

Page 28: ...ads an actual value from the internal PLC and returns it Min and Max are dependent of hardware configuration of plug in module PR1713 06 Plug in module Min 0 V bis 0 mA to 4 mA to Max 10 V 20 mA 20 mA...

Page 29: ...arse batching valve is closed During discharging B8 After weight below preset value the hopper is considered as discharged Only the adjusted discharge time must elapse before the valve closes The sele...

Page 30: ...prox 30 seconds Depen dent of measuring time resolution and total to be batched the flow alarm can also be output earlier The component flow can vary during normal operation e g the material starts fl...

Page 31: ...again Further correction is not possible With a tolerance alarm batching stops and the user has the opportunity for process interven tion In this case the process can be continued Go or aborted A Calc...

Page 32: ...atching Go restart mode 2 Calculate only a new overshoot in this mode Tolerance alarm Mode 3 S T S T Go A Restart Y N Restart J N Next component New overshoot New overshoot New overshoot Corrected ove...

Page 33: ...ent is found If other components must still be deleted the deleting operation is continued with soft key se lection next Key quit can be pressed to leave submenu delete 6 1 4 Printing Individual or al...

Page 34: ...e for this line Component select recipe Name Recipe name 27 Component name Quit Quit store yes no abc Parameter value remain unchanged abc changed parameter value is accepted With yes all changes for...

Page 35: ...he selected name is displayed in the upper line In the lower line all parameters can be selected The relevant line number is always displayed on the left It can be edited first The va lue of another p...

Page 36: ...e in seconds and has to be entered without a unit After completing the last parameter the next line number is always displayed automatically so that a quick survey of all data of a recipe is possible...

Page 37: ...xtension of a B2 component the pre vious B1 component must not used for the recipe sum calculation The fil up batch B2 is based on the last tare from the B1 and con tains in its setpoint so to speak t...

Page 38: ...0 kg 300 kg Recipe setpoint 300 kg Scaling factor 2 real batch run Recipe 3 B1 50 kg 50 kg B1 50 kg S 75 kg B3 200 kg T S 300 kg 200 kg 300 kg Recipe setpoint 300 kg Scaling factor 1 5 real batch run...

Page 39: ...ayed instead Leave submenu delete by pressing key quit 6 2 6 Printing Printing individual or all recipes with function print Select the entry by scrolling A list limitation is possible with Enter Pres...

Page 40: ...cycle The status display has two levels The display will change the level by pressing the key more In the first level the recipe name is shown in the upper line In the lower line the recipe line num b...

Page 41: ...y the overall recipe is aborted The menu is left again with the quit key 6 3 4 Messages during batching If tolerance monitoring is activated by entry of the tolerance parameters above zero a tolerance...

Page 42: ...read and deleted If reports are generated for eg com munication and user interface the communication has to detete the batch reports If not the data base is filled until no free memory space is left...

Page 43: ...Soft key selection Clear clears one or more production totals Soft key selection Show shows one or more production totals By pressing a key the productions are displayed one by one Pressing key quit t...

Page 44: ...fore the menue batchep auto prt has to be selected to auto Maier Keks GmbH The world of biscuits Batch report Date 03 10 99 12 35 Recipe cookies Sequence number 476 Total 100 kg Production number 12 C...

Page 45: ...f the digital I O modul PR1713 12 is plugged in Limit 1 on WP A A12 Limit 2 on WP A A34 Limit 1 on WP B A56 Limit 2 on WP B A78 Slot 3 Batching operation For the batching operation the licence PR1713...

Page 46: ...ded The output addresses of the components had to be entered in the parameter SPM out for each component The selection of the output is free For D1 D2 D5 and D8 components needs also the corresponding...

Page 47: ...ve MX1024 Free marker range for component output 256 bits to MX1279 MX1280 Free marker range for recipe number input 32 bits to MX1311 MX1312 Quit input for manual component on WP A internal WP MX1313...

Page 48: ...LSB 1279 MSB Value after coding 20 21 22 23 terminal A12 A34 A56 A78 Input signals for components The components for manual weighing D1 D2 need a Quit signal from the operator The address of the Quit...

Page 49: ...he test is activated the measuring signal is disconnected from the loadcell The displayed va lue appears without an unit on the weighing display Depending on the calibration the value is dis played as...

Page 50: ...Batching PR1713 Operating manual Seite 48...

Page 51: ...tion Configuration Serial interfaces Display of board number Licence number management Initialization data print out Set time Refresh display Reboot These functions are described in the Installation m...

Page 52: ...Setup PR1713 Operating manual Seite 50...

Page 53: ...mputer overflow faulty calibration values Error 2 The input voltage is above f s d overload Error 3 The input voltage is below the permissible value of 36mV However the message can also be due to an a...

Page 54: ...0 recipe lines are not numbered continuously 11 invalid PLC bit address 12 no function module existing 13 faulty function module type 14 parameter error in the function module 15 no free memory space...

Page 55: ...6 batching functions 19 C calculation mode 35 36 Calming time 28 29 charge discharge batching 24 component delete 31 editing 20 print out 31 component signal binary coded 43 46 single 43 45 Configurat...

Page 56: ...Point 27 print out key 7 production totals 41 Q Quit key 7 R Recipe delete 37 edit 32 print out 37 recipe setpoint 36 recipe sum 35 recipe total mode 35 Reports 40 restart mode 29 RW RQ RL 25 S scali...