[:INPut]:SCALing:{VT/PT|CT}:STATe
Description
Sets or returns the scaling vt/pt,ct on/off state.
Syntax
[:INPut]:SCALing:{VT/PT|CT}:STATe {<Boolean>}
Query Syntax
[:INPut]:SCALing:{VT/PT|CT}:STATe?
Parameter
<Boolean>0 OFF
<Boolean>1 ON
Return parameter 0
Turn the scaling vt/pt, ct function off.
1
Turn the scaling vt/pt, ct function on.
Example
:INPUT:SCALING:VT:STATE ON
:INPUT:SCALING:VT:STATE?
->:INPUT:SCALING:VT:STATE 1
[:INPut]:SCALing:{VT/PT|CT}:RATio
Description
Collectively Sets or returns the vt/pt ratio or ct
ratio.
Syntax
[:INPut]:SCALing:{VT/PT|CT|}:RATio {<NRf>}
Query Syntax
[:INPut]:SCALing:{VT/PT|CT}: RATio?
Parameter/
Return parameter
<NRf>
1.000 to 9999.999
Example
:INPUT:SCALING:VT:RATIO 1
:INPUT:SCALING:VT:RATIO?
->:INPUT:SCALING:VT:RATIO 1
[:INPut]:SYNChronize
Description
Sets or returns the synchronization source.
Syntax
[:INPut]:SYNChronize {VOLTage|CURRent|OFF}
Query Syntax
[:INPut]:SYNChronize?
Set
Query
Set
Query
Set
Query