GPM-8213 User Manual
82
Parameter/
Return parameter
Select the dc measurement mode.
Select the acdc measurement mode.
Select the ac mode.
Example
:INPUT:MODE DC
:INPUT:MODE?
->:INPUT:MODE DC
[:INPut]:VOLTage:RANGe
Description
Sets or returns the voltage range.
Syntax
[:INPut]:VOLTage:RANGe {<Voltage>}
Query Syntax
[:INPut]:VOLTage:RANGe?
Parameter/
Return parameter
<Voltage>
15, 30, 60, 150, 300, 600(V) when the
crest factor is set to 3.
7.5, 15, 30, 75, 150, 300(V) when the
crest factor is set to 6
Example
:INPUT:VOLTAGE:RANGE 600V
:INPUT:VOLTAGE:RANGE?
->:INPUT:VOLTAGE:RANGE 600.0E+00
[:INPut]:VOLTage:AUTO
Description
Sets or returns the voltage auto range on/off state.
Syntax
[:INPut]:VOLTage:AUTO {<Boolean>}
Query Syntax
[:INPut]:VOLTage:AUTO?
Parameter
<Boolean>0 OFF
<Boolean>1 ON
Return parameter 0
Turn the voltage auto range function off.
1
Turn the voltage auto range function on.
Set
Query
Set
Query