![GW Instek APS-7100 Programming Manual Download Page 84](http://html1.mh-extra.com/html/gw-instek/aps-7100/aps-7100_programming-manual_2279972084.webp)
APS-7000 Programming Manual
84
:SYSTem:KLOCk
Set
Query
Description
Enables or disables the front panel key lock.
Syntax
Query Syntax
:SYSTem:KLOCk {<bool>|OFF|ON }
:SYSTem:KLOCk?
Parameter
OFF | 0
Panel keys unlocked
ON | 1
Panel keys locked
Return parameter <bool>
Returns the key lock status.
:SYSTem:REBoot
Set
Description
Reboots the PSU system.
Syntax
:SYSTem:REBoot
:SYSTem:WRELease
Set
Description
Clears the protection circuits (OCP, OTP). This
command is functionally the same as
the :OUTPut:PROTection:CLEar command (page
61).
Syntax
:SYSTem:WRELease
All manuals and user guides at all-guides.com