![GW Instek APS-7100 Programming Manual Download Page 78](http://html1.mh-extra.com/html/gw-instek/aps-7100/aps-7100_programming-manual_2279972078.webp)
APS-7000 Programming Manual
78
Parameter
<NR2>
Tup in milliseconds
MINimum
Minimum Tup
MAXimum
Maximum Tup
<NR2>
Tdn in milliseconds
MINimum
Minimum Tdn
MAXimum
Maximum Tdn
Return parameter <NR2>,<NR2>
Returns the Tup,Tdn time.
Example
:SYST:CONF:RAMP:TIME?
>+3.0000,+4.0000
Returns the Tup,Tdn values.
:SYSTem:CONFigure[:MODE]
Set
Query
Description
Sets or queries the test mode for the power supply.
Syntax
:SYSTem:CONFigure[:MODE]
{<NR1>|CONTinuous|SEQuence|SIMulation}
Query Syntax
:SYSTem:CONFigure[:MODE]?
Parameter
0 | CONTinuous
Continuous mode (normal
operating mode)
1 | SEQuence
Sequence mode
2 | SIMulation
Simulation mode
Return parameter <NR1>
CONT
Continuous mode (normal operating
mode)
SEQ
Sequence mode
SIM
Simulation mode
:SYSTem:CONFigure:PHASe
Query
Description
Queries the phase of the system.
Query Syntax
:SYSTem:CONFigure:PHASe?
Return parameter +0
<NR1>Single phase
:SYSTem:CONFigure:SDIP[:MODE]
Set
Query
Description
Sets or queries the surge/dip mode for the power
supply or disables the surge/dip mode.
All manuals and user guides at all-guides.com