9.11
External Control I/O
APS-1102 Programmable AC/DC Power Source
9-13
9.11
External Control I/O
External control operation mode
Enabled or disabled (status output is continually output)
Control input
Input level
High level: +4.0 V or above, Low level: +1.0 V or below
Nondestructive
maximum
input:
+10
V/
5 V
Input impedance
+5 V pull-up with 47 k
Control item
Output off:
Output off at fall
Output on:
Output on at fall
Start sequence:
Start at fall
Stop sequence:
Stop at fall
Hold input:
Hold at fall
Branch inputs 0, 1: Start branch at fall
Status output
Output level
0/+5 V (open)
Output
impedance
100
Ω
Status items
Power source on/off status:
0-off, 1-on
Output on/off status:
0-off, 1-on
Limiter operation:
0- Not operating, 1- Operating
Software busy:
0- Normal, 1- Busy
Sequence operation step synchronized outputs 0 and 1
Terminals
D-sub 25-pin multi-connector (rear panel)
9.12
USB Interface
USB interface is provided to enable control from an external computer.
Interface standard: USBTMC
9.13
Power Input
Input voltage range:
100 V AC to 230 V AC ±10% (not exceeding 250 V)
Overvoltage
Category
II
Frequency range:
50 Hz or 60 Hz ±2 Hz (single phase)
Power consumption:
1.4 kVA or less
Power factor:
0.95 or above (during 100 V AC input)
0.90 or above (during 200 V AC input)
Protective ground impedance:
0.1
Ω
or less (not including the power cord set)