5.4 MEASURE Screen
APS-1102 Programmable AC/DC Power Source
5-23
5.4.1
Output voltage measurement
When “MEASURE” has been selected in the MISC menu, RMS value (RMS), average DC (AVG), or
peak value (PEAK) is displayed.
The initial setting (factory setting) is to display the RMS value (RMS).
See “3.4.9 Using measurement functions”.
a) RMS value
RMS value of AC+DC
Full scale:
±225.0 Vrms: 100 V range
±450.0 Vrms: 200 V range
Display resolution:
0.1 Vrms
Measurement accuracy: ±0.5% of the full scale (at 23 ±5°C)
b) Average value
Average value of AC+DC (measurement of DC)
Full scale:
±225.0 V: 100 V range
±450.0 V: 200 V range
Display resolution:
0.1 V
Measurement accuracy:
0.5% of the full scale (at 23 ±5°C)
c) Peak value
Positive peak voltage and negative
peak voltage are displayed
separately
Full scale:
+225 Vpk/
225 Vpk: 100 V range
+450 Vpk/
450 Vpk: 200 V range
Display resolution:
1 Vpk
Measurement accuracy:
3% of the full scale (at 23 ±5°C, sine wave)