6.3
Command Descriptions
APS-1102 Programmable AC/DC Power Source
6-23
[SOURce:]VOLTage:LIMit:LOW
This sets the upper limit of the output voltage that can be set. However, a value that is at or below
the currently set cannot be specified. ([5, “Out of Limiter”] error occurs.)
For the 100 V range, the limit value setting ranges from
200.0 to
5.0 V, and for the 200 V range,
it ranges from
400.0 to
10.0 V.
Syntax:
[SOURce:]VOLTage:LIMit:LOW <NR2>
Parameters:
200.0 to
5.0 (
400.0 to
10.0)
Command example:
VOLT:LIM:LOW
200
Query
example:
VOLT:LIM:LOW?
Response format:
<NR2>
Response
example:
200.0
[SOURce:]VOLTage:OFFSet[:IMMediate]
This sets the DC voltage when in AC+DC-INT, AC+DC-ADD, or AC+DC-SYNC mode. For the
100 V range, the DC output voltage setting ranges from
200.0 to 200.0 V, and for the 200 V range,
it range, from
400.0 to 400.0 V.
The DC output voltage cannot be set unless the mode is AC+DC-INT, AC+DC-ADD, or
AC+DC-SYNC mode. ([3, “Invalid in this mode”] error occurs.)
Syntax:
[SOURce:]VOLTage:OFFSet[:IMMediate] <NR2>
Parameters:
200.0 to 200.0 (
400.0 to 400.0)
Command example:
VOLT:OFFS 10
Query
example:
VOLT:OFFS?
Response format:
<NR2>
Response example:
10.0
[SOURce:]VOLTage:RANGe
This sets the output voltage range. The output voltage range setting is 100 V or 200 V.
However, when output is on, output voltage range cannot be changed. ([1, “Invalid with output
on”] error occurs.)
Syntax:
[SOURce:]VOLTage:RANGe <NR1>
Parameters:
100/200
Command example:
VOLT:RANG 100
Query
example:
VOLT:RANG?
Response format:
<NR1>
Response
example: 100