background image

“GF” SERIES AUTOMATIC WATER CONDITIONERS

INSTALLATION

5

C. Installation and Start Up

1.  Make sure all connections have been made:  Inlet, outlet, brine line installed and connected to the brine tank 

and control valve, drain line installed, and over flow drain tubing connected and run to the drain.  (DO NOT 

CONNECT DRAIN LINE AND OVERFLOW TUBING)

2.  If the unit is not in bypass please do so now.  If using a bypass purchased with the unit the unit will be in the 

bypass position when the two arrows on the handles of the bypass are pointing towards each other (see figure 

2 page 12).

3.  Turn on your main water supply.  Locate a cold soft water tap and turn it on, allow the water to run until all ex-

cess air and foreign material is removed from the water.

4.  Add seven (7) gallons of water to the brine tank.
5.  Plug the water softener into the designated receptacle.  Program the current time of day (see page 9 for in-

structions).

6.  Press and hold the REGEN button (located in the upper right hand corner) until the unit starts a regeneration 

(depending on how the unit is programmed the first cycle may be back wash or brine fill).  Once the piston 

stops moving and the unit is counting down press the REGEN key again.  This will advance the unit to the next 

cycle.  Repeat this process until you see the word RINSE in the upper left hand corner.  Slowly open the inlet 

side of the bypass (see page 13 figure 3).  Let the water run to the drain until the water runs clear.

7.  Place the bypass back into the bypass mode (see page 13 figure 2)
8.  Press the REGEN button again to cycle the unit to the next cycle.  Wait for the piston to stop moving and press 

the REGEN button again.  Repeat this until the unit is at the home screen.  The home screen will be blue in 

color.

9.  Press and hold the REGEN button again until the unit starts a regeneration.  Depending on how the unit it set 

up you might have to wait for the piston to stop moving and press the REGEN button again repeating several 

times till the word BACKWASH appears in the upper left hand corner.  On most units BACKWASH should ap-

pear at the first screen.

10. Slowly turn the handle of the incoming water (See page 13 figure 3) until the bypass valve is completely 

opened.  Once you have a solid flow of water to the drain, open the outlet side of the bypass (see page 13 

figure 1) to duplicate the normal operation.

11.  Press the REGEN button again to cycle the unit to the next cycle.  Wait for the piston to stop moving and press 

the REGEN button again.  Repeat this until the unit is at the home screen.  The home screen will be blue in 

color.

12. Set the incoming hardness of the water, time of regeneration and calendar override.  See page 8 Steps 1I 

through 6I.

13. Add salt to brine tank.

10. An overflow fitting is attached to the outside of the brine tank (overflow elbow is white in color).  Attach a 5/8 

drain line (do NOT connect overflow tubing with drain line tubing).  The overflow fitting is installed in case the 

unit would malfunction and water would continually run to the brine tank.  The overflow (if tubing is connected) 

would allow the excess water to be run to the drain rather than overflow onto the floor.  Do NOT run overflow 

tubing above the overflow elbow at any point.

Summary of Contents for GF24

Page 1: ...GF Series Water Softener INSTALLATION OPERATION AND MAINTENANCE MANUAL MODEL NO SERIAL NO DATE INSTALLED DEALER COMPLETE FOR FUTURE REFERENCE 8 569 G F R2...

Page 2: ...rine tank cabinet or solu tion container without charge You pay freight one way and local labor charges No allowance is made for consequential damage labor or expense incurred as a result of proven de...

Page 3: ...tallation Fitting Assemblies 3 Installation Procedures 4 OPERATION Control Valve Function and Cycles of Operation 7 Control Valve Programming 8 Flow Diagrams 12 Bypass Valve Operation 13 MAINTENANCE V...

Page 4: ...IN OUT INCHES 1 1 1 DRAIN SIZE INCHES 3 4 3 4 3 4 OPERATING PRESSURE MAX PSI 125 125 125 OPERATING TEMPERATURE MAX DEG F 110 110 110 MINERAL TANK SIZE DIA X HT 2 INCHES 8X44 10x47 12x52 BRINE TANK SI...

Page 5: ...5 ft High Pressure Warning If feedwater pressure is known to be above 100 p s i it is strongly recommended that a pressure reducing valve be installed at this point Hard water to Sprinklers and any d...

Page 6: ...ape is not necessary on the nut connection or caps because of o ring seals Do not use Vaseline oils or other hydrocarbon lubricants oanywhere on the control valve or resin tank assembly A silicon lubr...

Page 7: ...valve The bypass valve and the control valve are both marked with arrows that indicate the direction of water flow If water lines are reversed resin maybe forced from the water softener and into hous...

Page 8: ...13 figure 2 8 Press the REGEN button again to cycle the unit to the next cycle Wait for the piston to stop moving and press the REGEN button again Repeat this until the unit is at the home screen The...

Page 9: ...ime of day Activate Lockout Feature Press DOWN then NEXT then UP then CLOCK in sequence LOCK will briefly ap pear in the display De activate Lockout Feature Press DOWN then NEXT then UP then CLOCK UNL...

Page 10: ...g takes much less time than comparable products currently on the market Control valve installation is made easy because the distributor tube can be cut 1 2 above to 1 2 below the top of the tank threa...

Page 11: ...de using DOWN or UP number of days between regeneration 1 to 28 or OFF See Setting Options Table for more detail on setup Press NEXT to go to step 4I Press REGEN to return to previous step STEP 4I STE...

Page 12: ...for instructions The fth display will show either DP or HOLD if the dP switch is closed If the system has called for a regeneration that will occur at the pre set time of regeneration the words REGEN...

Page 13: ...usually referred to as manual regeneration There may be a period of heavy water usage because of guests or a heavy laundry day To initiate a manual regeneration at the preset delayed regeneration tim...

Page 14: ...ay will ash on and off which indicates the time of day should be reset and the non rechargeable battery replaced The system will remember the rest Error Message If the word ERROR and a number are disp...

Page 15: ...Y WATER TO TOP OF TANK CONDITIONED WATER FROM DISTRIBUTOR OUTLET PORT FOR SERVICE WATER flow diagram rinse flow diagram fill CONDITIONED WATER TO REGENERANT TANK SUPPLY WATER OUTLET PORT FOR SERVICE W...

Page 16: ...ndles point in the direction of flow indicated by the engraved arrows on the control valve Water flows through the control valve during normal operation and this position also allows the control valve...

Page 17: ...GF SERIESAUTOMATIC WATER CONDITIONERS MAINTENANCE 14 Drive Cap Assembly Downflow Piston Regenerant Piston and Spacer Stack Assembly Front Cover and Drive Assembly t t t 14...

Page 18: ...1 14 A2242054 Transformer 110V 12V 1 Drive Cap Assembly Downflow Piston Upflow Piston Regenerant Piston and Spacer Stack Assembly Item No Part No Description Quantity 1 A2466034 Spacer Stack Assembly...

Page 19: ...9 27 28 31 21 Injector Cap Injector Screen Injector Plug O Ring Refill and Refill Port Plug Drain Line 3 4 Proper flow washer orientation directs water flow towards the washer face with rounded edge F...

Page 20: ...Washer 1 7 gpm for 3 4 A2253081 Drain Flow Washer 2 2 gpm for 3 4 A2253082 Drain Flow Washer 2 7 gpm for 3 4 A2253085 Drain Flow Washer 3 2 gpm for 3 4 A2253086 Drain Flow Washer 4 2 gpm for 3 4 A2253...

Page 21: ...mplete Specify Model A2042018 2 Brine Tank w Cover A2071005 3 Brine Well A2072003 4 Brine Well Cap A2250003 5 Overflow Elbow A2118010 6 Brine Tube w Air Check B1020001 7 Brine Line Hose w Inserts A200...

Page 22: ...95069 Nut 1 Quick Connect 1 37 A2360039 Meter Assembly 1 38 A2100027 Turbine Assembly 1 39 use item 51 O Ring 215 Use Valve O ring Kit 1 40 A2287077 Meter Plug Assembly Time clock option 1 Item 37 inc...

Page 23: ...395009 Bypass Handle 2 47 A2104036 Bypass Rotor Seal Retainer 2 48 use item 52 O Ring 135 use Bypass Valve Kit 2 49 use item 52 O Ring 112 use Bypass Valve Kit 2 50 use item 52 O Ring 214 use Bypass V...

Page 24: ...n Quantity 1 A2095069 Nut 1 Quick Connect 2 2 A2453012 Split Ring 2 3 A2077178 O Ring 215 2 4 A2569008 Fitting 3 4 1 PVC Solvent 90 2 Order No A2435072 Optional Description Fitting 3 4 Brass Sweat Ass...

Page 25: ...been ser viced b Foreign matter is lodged in control valve c High drive forces on piston d Control valve piston not in home position e Motor not inserted fully to engage pinion motor wires broken or d...

Page 26: ...ion b Meter connection disconnected c Restricted stalled meter turbine d Defective meter e Defective PC board f Set up error a Power has been out more than two hours the transformer was unplugged and...

Page 27: ...GF SERIESAUTOMATIC WATER CONDITIONERS NOTES...

Page 28: ...8 569 G F R2...

Reviews: