USER MANUAL- Termonebulizadora Guskiner 1980'S Fogger Pro
5.3, When the outside temperature is too low, the
machine will power off instantaneously. In this case, you
need to long press the start button after the machine is
started and open the solution valve meanwhile until the
machine works normally.
6. Notes
1, The machine is strictly prohibited to be used in flammable and explosive places.
2, The machine uses gasoline as fuel, attention should be paid to fire fighting, ignition and smoking is strictly
prohibitted neat the machine.
3, It is strictly prohibited to open the carburetor to check igniter ignition.
4, The oil tank cover should be tightened after the oil is filled, the leakage of fuel should be cleaned and the
machine should be started far away from the refueling site.
5. It is prohibited to fill or dump the oil when the machine is in operator or just stopped.
6, In operation, the high temperature parts can not touch people or animals, to avoid accidental injury, see
figure 2. Forcibly cooling with water after the machine is stopped is strictly prohibited, wich can seriously
damage the machine.
7, For the health of operators, when working in the field, the operator should stand in the uptake of the nozzle
to operate and should not walk along the direction of the wind. When working indoors, the operator should
spray from the inside to the outside. When the operator comes to the door, he stops the machine and closes
the door after coming out from the room the ensuere the personal safety and effective killing o f the insect
or virus.
8, It is prohited to use electric arc or acetylene welding method for welding or cutting on the machine with
pesticides or gasoline residues, When the oil tank or pesticide solution tank leaks, please contact the dealer
or professional after-sales service personnel to handle.
9, When the residual pesticides or washing liquid of the perticide tank is handled, please follow the safety
instructions provided by the pesticides manufacturer.
10, After the machine completes its work, please close the pesticide solution valve and then turn off the engine
or do both actions at the same time; if the engine unexpectedly flameout, please close the valve quickly
11, Empty the fuel inside the oil tnak and carburretter before the machine is stored. For products of electrical
series, the pesticide tank and pump shall be cleaned also, the place the machine in ventilated place away
from fire. For long time storing, the machine should be charged every 30 days and each time for 5 hours.
12, The machine should be placed in a place away from children to avoid accidents