USER MANUAL- Termonebulizadora Guskiner 1980'S Fogger Pro
2. Check the ckeck valve of the solution tank gas inlet is not damaged. (Note: do not install it in wrong way. The
principle is: the gas goes into the solution tank from the machine and not return back-)
3, Check if the pipeline and the solution inlet screw is blocked.
Note: if you have any other questions, please contact the
manufacturer.
7. Regular maintenenance and long-term storage
(a) Regular maintenance
1. Daily maintenance (/shift)
(1) Clean up the oil or and dust on the surface of the gasoline engine.
(2) Strict filtraion before the oil or pesticidee solution is filled, keep the filling appliance clean, to prevent
sundries into the fuel tank and the solution tank.
(3) For both oil and pesticide solutions, check whether the pipe connection leaks, whether the pipe is
open.
2. Maintenance per 50 hours (according to the machine running hours)
(1) Complete daily maintenance work.
(2) Clean oil tank.
(3) Clean the pesticide solution tank.
Clean the tank with boiling water: add 500ml-2000ml of boiling water to the tank, shake the tank
emphatically and open the valve to empty the wtaer into the container. Thee cleaning water is handled
according to te instructions of pesticide manufacturer.
(4) Clean the carbon desposition on the nozzle, carburetor chamber and ignition needle and clean the
inlet valve