USER MANUAL- Termonebulizadora Guskiner 1980'S Fogger Pro
¡Be careful!
Please do not disassemble carburetor chamben. For its maintanance,
please contact professional service people. If there is problem with it
please contact the dealer or service network station
3, Maintenance per 100 hours (according to the machine running hours)
(1) Complete the maintenance work per 50 hours.
(2) Clean the carbon deposition on various parts.
(3) Empty the oil and pesticide solution, clean the solution tank and
pipe with boiling water to check if the pipe is blocked.
(4) Check the pipes and screws to see if there is any loose or fallen off.
(5) Check the ignition system, to ensure the cable and connections is
good and ignition needle works well.
4, Maintenance per 500 hours (according to the machine running hours)
Dismantle the whole machine (except the carburetor chamber) to clean
and check, including the wearing parts and sealings. If there is any parts
damaged or worn, it shall be repaired or replaced.
(b) Long term storage
Empty the fuel tank.
1. Clean the gas intake diaphragm, and reassemble them.
2. Clean the pesticide solution tank and pipe with boiling water.
3. Clean the carbon deposition on all various parts and recharge the
battery. (recharge once every 4 months for a long time no use).
4. Clean every parts.
5. Check each part, replace the damaged parts timely
6. Store the machine in a vetilated and dry warehouse.