Operator's guide
You can now enable the AutoDRM system under Data transfer—AutoDRM.
Click Save changes to start the service.
To test the AutoDRM system, send the following e-mail to the DCM:
From:
To: autodrm@
your.DCM
BEGIN GSE2.0
MSG_TYPE request
MSG_ID
unique-identifier
HELP
STOP
where
is the e-mail address to send the return
message and
unique-identifier
is a string which you can use to identify
your request.
autodrm@
your.DCM
should be replaced with an e-mail address
which will be delivered to the
autodrm
mailbox on the DCM.
The DCM should send a mail back to you containing help on the commands
you can give the AutoDRM.
3.5 Troubleshooting DCM installations
I cannot connect to the DCM's DATA OUT port using a terminal
program.
Press
ENTER
a few times to initiate communication.
If the DATA OUT port gives a
login
prompt, you should log in with your
username and password. If you have not been given a different username and
password, try logging in as
root
with the password
rootme
. You should
change this password as soon as you can with the command
passwd
If the DATA OUT port gives an
ok
prompt, the DCM is running the gcf_out
service on that port and has provided you with a FORTH compatibility
interface. Type
GETTY
and press
ENTER
to gain access to the login prompt.
If the DATA OUT port does not respond when you press
ENTER
, or produces
garbage, check that your terminal program is using the same baud rate as the
DCM. By default, the DCM uses a baud rate of 115200, with 8 data bits, no
parity bit and 1 stop bit, and no flow control.