Installation

12

 · G&D FIBREVision

Additional interfaces of the multi-channel variants

Transmission – Tx: 

Insert the LC plug of the fibre optic cable (available as accessories)

into this interface. Connect the other end of the cable to the 

Transmission – Rx

 inter-

face of the computer module.

Transmission – Rx: 

Insert the LC plug of the fibre optic cable (available as accessories)

into this interface. Connect the other end of the cable to the 

Transmission – Tx

 inter-

face of the computer module.

DVI/VGA Out: 

Connect the console monitor to this interface.

If the monitor only provides an analog VGA input, connect an optional adapter to this 

interface. Afterwards, connect the monitor’s VGA cable to the adapter

Figure 7: Additional interfaces of the multi-channels variants at the user module

NOTE: 

For each additional video channel, the multi-channel variants of the user mod-

ule are additionally provided with the interfaces 

Transmission -Tx, Transmission - Rx

and 

DVI/VGA Out

.

The interfaces of each channel are located next to each other. The interfaces are 

provided with the numbers of the channels.

Summary of Contents for FIBREVision

Page 1: ...G D FIBREVision DE Installation und Bedienung EN Installation and Operation Guntermann Drunck GmbH www gdsys de A9100096 1 70...

Page 2: ...immt keine Gew hrleistung f r Ger te die nicht bestimmungsgem eingesetzt wurden nicht autorisiert repariert oder modifiziert wurden schwere u ere Besch digungen aufweisen welche nicht bei Lieferungser...

Page 3: ...IBREVision Systems 14 Exklusive Bedienung des FIBREVision Systems 14 Konfiguration 15 bersicht der Funktionen und Standardeinstellungen 15 Vorgehen zur nderung der Konfiguration 16 Bedienung des Setup...

Page 4: ...ichtungen und Abst nde der Ger te 47 Temperaturwarnungen 48 USB und PS 2 Signale der Varianten ARU und U 48 Unterst tzung beliebiger Grafikaufl sungen 48 Statusanzeigen 50 Rechnermodul FIBREVision CPU...

Page 5: ...sversorgung am Ger t ab St ndigen Zugang zu den Netzsteckern der Ger te sicherstellen Achten Sie bei der Installation der Ger te darauf dass die Netzstecker der Ger te jederzeit zug nglich bleiben L f...

Page 6: ...ken Decken Sie die optischen Anschl sse der Transmission Buchse und die Kabelstek ker stets mit einer Schutzkappe ab wenn diese nicht verbunden sind Ausschlie lich von G D zertifizierte bertragungsmod...

Page 7: ...n die entfernte Bedienung des Rechners Die Bedienung des Rechners kann wahlweise am entfernten Arbeitsplatz des Arbeitsplatzmoduls oder am lokalen Arbeitsplatz des Rechnermoduls erfolgen Verf gbare Ge...

Page 8: ...maximale Entfernung von 550 Metern Die Signal bertragung auf diesen Fasern erfolgt ber viele verschiedene Licht wege wodurch es zu Signalbeeinflussungen kommt Daher sind Multimode Fasern f r gro e Di...

Page 9: ...ben haben befin den sich zus tzlich folgende Kabel im Lieferumfang 2 Audio Kabel Audio M M 2 1 serielles Anschlusskabel RS232 M F 2 Zus tzlicher Lieferumfang der Multi Channel Varianten Die Multi Chan...

Page 10: ...tzes HINWEIS Die Ger te verwenden Baugruppen mit Laser Technologie die der Laser Klasse 1 entsprechen Sie erf llen dabei die Richtlinien gem DIN EN60825 1 2001 11 IEC 60825 1 sowie U S 21 CFR 1040 10...

Page 11: ...Stecker des Twin PS 2 Kabels Mouse CPU Verbinden Sie die gr nen PS 2 Buchse Maus des Rechners mit dieser Schnittstelle Verwenden Sie hierzu den gr nen Stecker des Twin PS 2 Kabels Zus tzliche Schnitts...

Page 12: ...der Schnittstelle Transmission Rx des Arbeitsplatzmoduls zu verbinden Transmission Rx Stecken Sie hier den LC Stecker des als Zubeh r erh ltlichen Glas faserkabels ein Das andere Ende des Kabels ist m...

Page 13: ...okalen Arbeitsplatzes an Ist der Monitor nur mit einem analogen VGA Eingang ausgestattet stecken Sie einen optionalen Adapter auf diese Schnittstelle Schlie en Sie anschlie end das VGA Kabel des Monit...

Page 14: ...1 Devices An diese Schnittstellen zwei befinden sich an der R ckseite und zwei weitere an der Frontseite des Ger ts k nnen beliebige USB Ger te ange schlossen werden Die Datenrate der Schnittstellen...

Page 15: ...abels ist mit der Schnittstelle Trans mission Tx des Rechnermoduls zu verbinden Power Stecken Sie hier das mitgelieferte Kaltger tekabel PowerCable 2 Standard ein Red Power Optional kann ber diese Buc...

Page 16: ...t Schlie en Sie hier den Monitor des Arbeitsplatzes an Ist der Monitor nur mit einem analogen VGA Eingang ausgestattet stecken Sie einen optionalen Adapter auf diese Schnittstelle Schlie en Sie anschl...

Page 17: ...ten Sie das Rechnermodul FIBREVision CPU am Schalter oberhalb der Power Buchse sein 3 Schalten Sie den am Rechnermodul angeschlossenen Rechner ein Nach dem Einschalten des FIBREVision Systems signalis...

Page 18: ...Bedienung des FIBREVision Systems Um die exklusive Bedienung des FIBREVision Systems durch einen Arbeitsplatz zu erm glichen kann die Berechtigung f r dauerhaften Zugriff des Arbeitsplatzes im Setup...

Page 19: ...ktionen des FIBREVision Systems k nnen ausschlie lich im Setup Modus bzw Setup Men ausgef hrt werden Beachten Sie diesbez glich die Hinweise auf den folgenden Seiten Funktion Standard Seite Aktivierun...

Page 20: ...am Arbeitsplatzmodul die gelbe User LED Jetzt besteht die M glichkeit eine Setup Funktion auszuf hren So f hren Sie eine Setup Funktion aus Bet tigen Sie nach der Aktivierung des Setup Modus einen der...

Page 21: ...eine Verwenden Sie das mitgelieferte Servicekabel um den Rechner mit der Service Buchse an der Frontseite des Rechnermoduls zu verbinden So starten Sie das Setup Men Starten Sie das Terminalemulations...

Page 22: ...ive Zeile wird durch die eckigen Pfeile an den R ndern der Zeilen angezeigt Men punkte deren Einstellungen in der rechten Spalte angezeigt werden k n nen durch mehrfache Bet tigung der Leertaste ge nd...

Page 23: ...on Hotkey Backspace Vorgabe Strg Backspace gleichzeitig Bei aktivierter Hotkey Verz gerung halten Sie die Tastenkombination sieben Sekunden lang gedr ckt 2 Bet tigen Sie einen der unten angegebenen Se...

Page 24: ...Modus 1 Bet tigen Sie zur Aktivierung des Setup Modus die Tastenkombination Hotkey Backspace Vorgabe Strg Backspace gleichzeitig Bei aktivierter Hotkey Verz gerung halten Sie die Tastenkombination sie...

Page 25: ...ter Hotkey Verz gerung halten Sie die Tastenkombination sieben Sekunden lang gedr ckt 2 Bet tigen Sie einen der unten angegebenen Setup Keys um einen bestimm ten Hotkey zu aktivieren Strg Aktivierung...

Page 26: ...ang gedr ckt 3 Bet tigen Sie einen der unten angegebenen Setup Keys um den gew nsch ten Doppel Hotkey zu aktivieren Strg Aktivierung des Doppel Hotkeys Strg Shift Alt Aktivierung des Doppel Hotkeys Al...

Page 27: ...ebenen Setup Keys um ein bestimmtes Scancode Set zu aktivieren 2 Aktivierung des Scancode Sets 2 f r PS 2 Tastatureingaben 3 Aktivierung des Scancode Sets 3 f r PS 2 Tastatureingaben 3 Schalten Sie da...

Page 28: ...rden Setup Men 1 Starten Sie mit dem Terminalemulationsprogramm den Verbindungsauf bau zum FIBREVision System 2 M chten Sie diese Einstellung f r den lokalen Arbeitsplatz ndern w hlen Sie mit den Pfei...

Page 29: ...Rechner mit einem der unterst tzten Wacom Stift Displays oder Tabletts bedienen Controller Der Multimedia Controller ShuttlePRO v2 wird zur Bedienung verschie dener Audio und Videoprogramme genutzt Ei...

Page 30: ...n punkt USB Keymode mit den Pfeiltasten 3 W hlen Sie die gew nschte Einstellung s Tabelle auf Seite 25 mit der Leertaste 4 Bet tigen Sie die Taste S um die Einstellung zu speichern WICHTIG Haben Sie d...

Page 31: ...der innerhalb des Bereichs von 1 bis 90 Sekunden eingestellt werden So ndern Sie die Zeitspanne der Eingabesperre Verwandtes Thema Exklusive Bedienung des FIBREVision Systems auf Seite 14 HINWEIS Dies...

Page 32: ...Blinken der Rollen LEDs an den Tastaturen beider Arbeitspl tze signalisiert So de aktivieren Sie die Berechtigung f r dauerhaften Zugriff des Arbeitsplatzes Verwandte Themen Exklusive Bedienung des FI...

Page 33: ...zes Verwandte Themen nderung der Zeitspanne der Eingabesperre auf Seite 27 Berechtigung f r dauerhaften Zugriff des Arbeitsplatzes auf Seite 28 HINWEIS Diese Funktion kann ausschlie lich im Setup Men...

Page 34: ...eingelesenen EDID Daten des in der Spalte Current EDID angezeigten Monitors werden in diesem Modus dauerhaft gespeichert und ange wendet Bei Anschluss eines anderen Monitors werden dessen EDID Daten...

Page 35: ...eblendet sobald die Verbindung erfolgreich wiederhergestellt ist So w hlen Sie de aktivieren Sie die Freeze Funktion HINWEIS Diese Funktion kann ausschlie lich im Setup Men ein bzw ausge schaltet werd...

Page 36: ...ren Abh ngig vom Bildinhalt sind m glicherweise leichte Farbstufen erkennbar Latenzen Durch die zus tzliche Verarbeitung des Videosignals entsteht im HDIP Modus eine kurze Verz gerung bevor das Bild w...

Page 37: ...nden Sie die Tasten Pfeil bzw Pfeil um die Zeile Video Optimisation auszuw hlen und bet tigen Sie die Eingabetaste 3 Optional W hlen Sie mit den Tasten Pfeil bzw Pfeil die Spalte des Videokanals desse...

Page 38: ...Keys zur Verf gung So erreichen Sie die Aktivierung oder einen Reset der PS 2 Maus HINWEIS Sowohl die Aktivierung als auch der Reset einer PS 2 Maus k nnen ausschlie lich im Setup Modus durchgef hrt w...

Page 39: ...e nen Kan len umgeschaltet werden Show Temperature Info Anzeige der Temperatur innerhalb des Moduls Die Tasten R und L erlauben die Umschaltung zwischen den Eigenschaften des ent fernten remote und de...

Page 40: ...Die Aktualisierung der angezeigten Informationen ist mit der Taste U m glich 4 Bet tigen Sie die Taste Q um wieder in das Hauptmen zu gelangen Setup Modus 1 Bet tigen Sie zur Aktivierung des Setup Mod...

Page 41: ...B Emulation verwendet Hierf r wird dem Rechner ein USB HID Human Interface Device zur Verf gung gestellt Falls eine Besonderheit Ihrer Arbeitsumgebung die permanente Ausschaltung der USB HID Emulation...

Page 42: ...ystems auswirken Aktivieren Sie bei der Feststellung von Performanceeinbu en die niedrige oder die hohe Rauschfilterstufe die zur Angleichung der Fl chen Farbwerte f hrt und somit die Kompression erm...

Page 43: ...altet Standard X niedrige Rauschfilterstufe C hohe Rauschfilterstufe Setup Men 1 Starten Sie mit dem Terminalemulationsprogramm den Verbindungsauf bau zum FIBREVision System 2 W hlen Sie mit den Pfeil...

Page 44: ...s und bet ti gen Sie die Eingabetaste 3 W hlen Sie mit den Pfeiltasten die Zeile Set PLL bandwidth aus und bet tigen Sie die Eingabetaste 4 Optional Bewegen Sie bei Einsatz einer Multichannel Variante...

Page 45: ...ngen wieder her Setup Men 1 Starten Sie mit dem Terminalemulationsprogramm den Verbindungsauf bau zum FIBREVision System 2 W hlen Sie mit den Pfeiltasten die Zeile Special extended options aus und bet...

Page 46: ...der Kommandos Abfrage neuer Ereignisse GETLOG W hrend des Betriebs des KVM Extenders werden die 32 zuletzt aufgetretenen Ereignisse protokolliert Ist der Puffer f r neue Ereignisse belegt wird bei Auf...

Page 47: ...lug disconnected DVI Kabel Rechnerseite abgezogen DVI Signal loss kein DVI Signal mehr vorhanden DVI Signal ok DVI Signal erkannt Monitor connected Kabelverbindung zum Monitor hergestellt Monitor disc...

Page 48: ...oInput StatusLocal OK StatusLocal StatusRemote FAIL StatusRemote USBStatus Mode TRANS OK USBStatus STATUS Feld Beschreibung Zustand FreezingActive Freeze Funktion aktiv YES NO LocalVideoInput G ltiges...

Page 49: ...des KVM Extenders DIAG Ver 1 ReqID 123 Resolution 1600x1200 Resolution TemperatureLocal 35 TemperatureLocal TemperatureRemote 37 TemperatureRemote STATUS Feld Beschreibung Wert Resolution Aufl sung de...

Page 50: ...mware Version des Rechnermoduls CPU Versionsnummer FirmwareRemote Firmware Version des Arbeitsplatzmoduls CON Versionsnummer MonitorManufacturer Hersteller des Monitors aus DDC ausgele sener Wert Moni...

Page 51: ...reier Raum von mindestens 7 9 mm entspricht der H he der Ger tef e emp fohlen Ger teseiten mindestens 5 cm Ger teoberseite mindestens 3 cm Ger teunterseite mindestens 7 9 mm entspricht der H he der Ge...

Page 52: ...s Unterst tzung beliebiger Grafikaufl sungen Grunds tzlich unterst tzt das FIBREVision System jede Aufl sung die ber eine Single Link Schnittstelle gem DVI Spezifikation 1 0 bertragen werden kann Dies...

Page 53: ...en Arbeitsplatzes wei tergegeben Frequenzen und Bildlage des Signals am Rechnermodul entsprechen somit jenen des Grafikkartenausgangs HINWEIS Einige Grafikkarten unterscheiden bei der Erstellung des V...

Page 54: ...altet oder die Verbindung des Ger ts mit dem Stromnetz nicht hergestellt Pr fen Sie den korrekten Anschluss des Kaltger tekabels Red an Das optionale Netzteil ist angeschlossen und eine Spannung von 1...

Page 55: ...t nicht korrekt angeschlossen Sys an System betriebsbereit blinkt langsam Interne Kommunikation fehlerhaft Schalten Sie das Ger t aus und wieder ein blinkt Setup Modus aktiviert blinkt schnell Die Tem...

Page 56: ...ss eines Panels am Arbeitsplatzmodul 2 2 poliges Verbindungskabel 0 4 Meter 2 2 poliges Verl ngerungskabel 0 4 Meter Funktionsweise Die Fernbedienung der Taster ATX Power und Reset des Rechners erfolg...

Page 57: ...Rechner Geh uses auf diese Pins Falls die L nge des Kabels nicht ausreicht kann dieses mit einem der Verl ngerungskabel erweitert werden Pwr MB Verbinden Sie diese Pins mit der zuvor notierten Steckp...

Page 58: ...erung FIBRE Power Die Funktionen der Taster des Panels entsprechen den Funktionen des ATX Power und Reset Tasters am Geh use des Rechners Abbildung 8 Schnittstelle Power Card am Rechnermodul FIBREVisi...

Page 59: ...nung der Pins zu den Funktionen des Panels Um eines der Signale ATX Power oder Reset zu schalten ist das Signal mit dem gemeinsamen Minus Kontakt Pin 4 leitend zu verbinden Abbildung 10 Zuordnung der...

Page 60: ...splatz Monitor siehe spezifische Eigenschaften PS 2 Tastatur Maus 2 PS 2 Buchse USB Tastatur Maus 2 USB A Buchse Audio Varianten AR ARU 3 5 mm Klinkenbuchse Speaker 3 5 mm Klinkenbuchse Micro In USB 1...

Page 61: ...ARU bertragungsart transparent bertragungsrate max 115 200 bit s bertragene Signale RxD TxD RTS CTS DTR DSR DCD Update Verfahren lokale Service Buchse Schnittstelle 1 Mini USB Buchse Typ B Hauptstrom...

Page 62: ...m eloxiert Dimensionen B H T 210 44 210 mm Desktop 19 1 HE 210 mm Rackmount Gewicht ca 1 3 kg Einsatzumgebung Temperatur 5 bis 45 C Luftfeuchte 20 80 nicht kondensierend FIBREVISION CON Schnittstellen...

Page 63: ...Buchse Geh use Material Aluminium eloxiert Dimensionen B H T 435 44 210 mm Gewicht ca 3 1 kg Einsatzumgebung Temperatur 5 bis 40 C Luftfeuchte 20 80 nicht kondensierend FIBREVISION MC2 CON Schnittstel...

Page 64: ...verzinkt unten Dimensionen B H T 435 44 285 mm Gewicht ca 3 4 kg Einsatzumgebung Temperatur 5 bis 35 C Luftfeuchte 20 80 nicht kondensierend FIBREVISION MC4 CON Schnittstellen f r entfernten Arbeitsp...

Page 65: ...t200MHz km Leistungsdaten Wellenl nge 850 nm 770 nm bis 860 nm OptischeAbgabeleistung PAVG in 50oder62 5 m MMF 9 5 dBm bis 3 dBm Empfangsempfindlichkeit PMIN 17 dBm Empfindlichkeit Stressed PS 13 5 dB...

Page 66: ...CPU 100 240V 60 50Hz 0 5 0 2A 22W 100VAC 22W 240VAC MC2 U CON 100 240V 60 50Hz 0 6 0 3A 32W 100VAC 32W 240VAC MC2 AR CPU 100 240V 60 50Hz 0 5 0 2A 22W 100VAC 22W 240VAC MC2 AR CON 100 240V 60 50Hz 0...

Page 67: ...2 0A 22W 12VDC MC2 CPU 12VDC 1 7A 18W 12VDC MC2 CON 12VDC 1 5A 16W 12VDC MC2 U CPU 12VDC 1 7A 18W 12VDC MC2 U CON 12VDC 2 4A 26W 12VDC MC2 AR CPU 12VDC 1 7A 18W 12VDC MC2 AR CON 12VDC 1 5A 17W 12VDC...

Page 68: ...vide warranty for devices that Are not used as intended Are repaired or modified by unauthorized personnel Show severe external damages that was not reported on the receipt of goods Have been damaged...

Page 69: ...ation of the FIBREVision system 14 Exclusive operation of the FIBREVision system 14 Configuration 15 Overview of the functions and the default settings 15 Changing the configuration 16 Operating the s...

Page 70: ...d device adjustments and distances 46 Temperature warnings 47 USB and PS 2 signals of ARU and U variants 47 Support of any resolution 47 Status displays 49 Computer module FIBREVision CPU 49 User modu...

Page 71: ...ce has been disconnected from the power source Disconnect the main power plug or the power supply of the device Ensure constant access to the power plugs During the installation of the devices ensure...

Page 72: ...ways connect optical connections or cover them with protection caps Always cover the optical connections of the Transmission socket and the cable plugs with a connector or a protection cap Only use G...

Page 73: ...e users to operate the computer remotely The computer can be operated either at the remote console of the user module or at the local console of the computer module Available variants The FIBREVision...

Page 74: ...ese fibres the signals are transmitted through many different opti cal path lengths Thus the signal is influenced Multimode fibres are therefore not suited for bridging great distances Singlemode fibr...

Page 75: ...f delivery additionally includes the following cables 2 audio cable Audio M M 2 1 serial connection cable RS232 M F 2 Additional scope of delivery of multi channel variants The multi channel variants...

Page 76: ...le and the devices of the user console IMPORTANT The devices use components with laser technology which comply with laser class 1 They meet the requirements according to DIN EN 60825 1 2001 11 IEC 608...

Page 77: ...erface of the computer to this interface Mouse CPU Use the green plug of a Twin PS 2 cable to connect the PS 2 mouse interface of the computer to this interface Additional interfaces of FIBREVision AR...

Page 78: ...rface Connect the other end of the cable to the Transmission Rx inter face of the user module Transmission Rx Insert the LC plug of the fibre optic cable available as accessories into this interface C...

Page 79: ...tor of the local console to this interface If the monitor only provides an analog VGA input connect an optional adapter to this interface Afterwards connect the monitor s VGA cable to the adapter DVI...

Page 80: ...be connected to these interfaces Two USB interfaces are located on the back panel of the device another two can be found on the front panel The data rate of the interfaces is 12 MBit s USB 1 1 The USB...

Page 81: ...accessories into this interface Connect the other end of the cable to the Transmission Tx inter face of the computer module Power Insert the supplied PowerCable 2 Standard IEC cable Red Power Connect...

Page 82: ...sion Tx inter face of the computer module DVI VGA Out Connect the console monitor to this interface If the monitor only provides an analog VGA input connect an optional adapter to this interface After...

Page 83: ...turn on the computer module FIBREVision CPU 3 Turn on the computer which is connected to the computer module After the FIBREVision system has been switched on the LEDs on the front panel of both the...

Page 84: ...ation of the FIBREVision system For operating the FIBREVision system exclusively the function Authorising permanent activation of input lock can be activated in the setup menu If this function is swit...

Page 85: ...rd setting Page Activating the hotkey delay enabled 19 Using single or double hotkeys single hotkeys 20 Changing the single hotkey Ctrl 21 Changing the double hotkey Ctrl Shift 22 Changing the scancod...

Page 86: ...ssful activation of the setup mode is displayed by the blinking NUM and Scroll control LEDs on the keyboard Additionally the yellow User LED will blink at both the computer module and the user module...

Page 87: ...cable to connect the computer to the Service socket on the front of the computer module How to call up the setup menu Start the terminal emulator Load the connection settings of the setup menu and est...

Page 88: ...angular arrows Menu items whose settings are displayed in the right column can be changed by pressing the Space key repeatedly A menu item that has a sub dialogue available can be opened by pressing E...

Page 89: ...Hotkey Backspace default Ctrl Backspace to enable the setup mode If the hotkey delay is active press the key combination for seven seconds 2 Press one of the setup keys listed below to de activate th...

Page 90: ...22 Setup mode 1 Press Hotkey Backspace default Ctrl Backspace to activate the setup mode If the hotkey delay is active press the key combination for seven seconds 2 Press one of the setup keys listed...

Page 91: ...If the hotkey delay is active press the key combination for seven seconds 2 Press one of the setup keys listed below to activate a certain hotkey Ctrl activates the hotkey Ctrl Alt activates the hotk...

Page 92: ...nds 3 Press one of the setup keys listed below to activate the desired double hotkey Ctrl activates the double hotkey Ctrl Shift Alt activates the double hotkey Alt Shift Alt Gr activates the double h...

Page 93: ...s listed below to activate a particular scancode set 2 activates the scancode set 2 for PS 2 keyboard inputs 3 activates the scancode set 3 for PS 2 keyboard inputs 3 Restart the FIBREVision system Af...

Page 94: ...inal emulator to establish the connection to the FIBREVision system 2 Use the arrow keys to select the row PS 2 Keyboard Type CPU if you want to change this setting for the local console Use the arrow...

Page 95: ...ne of the supported Wacom pen displays or tablets Controller With the multimedia controller ShuttlePRO v2 you can operate audio and video programs You can use a special USB keymoade to use the control...

Page 96: ...2 Use the arrow keys to select USB Keymode 3 Use Space to select your settings see table on page 25 4 Press S to save your settings IMPORTANT If you change the keymode of the Sun Keyboard you need to...

Page 97: ...the input lock can be adjusted from 1 to 90 seconds How to set the timeout of the automatic input lock Related topic Exclusive operation of the FIBREVision system on page 14 NOTE This function can onl...

Page 98: ...vated at one console the Scroll LEDs are blinking on the keyboards of both users How to de activate the Authorising permanent console access function Related topics Changing the timeout of the automat...

Page 99: ...Related topics Changing the timeout of the automatic input lock on page 27 Authorising permanent console access on page 28 NOTE This function can only be de activated in the setup menu Setup menu 1 U...

Page 100: ...s of the last connected monitor or the default settings are still provided in the FIBREVision system Keep stored EDID The EDID data of the monitor shown in the Current EDID column is stored and always...

Page 101: ...ed frame disappears as soon as the conenction is re established successfully How to enable disable the Freeze function NOTE This function can only be de activated in the setup menu Setup menu 1 Use th...

Page 102: ...o be transmitted Depending on the image contents this may cause slight colour gra diations Latencies The additional processing of the video signal cuase a short latency in the HDIP mode This latency m...

Page 103: ...EVision system 2 Use the arrow keys to select the row Video Optimisation and press Enter 3 Optional Use the arrow or arrow keys to select the column of the video channel whose settings you want to edi...

Page 104: ...he installed operating system four different setup keys are provided How to activate or reset a PS 2 mouse NOTE A PS 2 mouse can only be activated or reset in the setup mode Setup mode 1 Press Hotkey...

Page 105: ...ocal module In this context the local module is always the module the data cable is con nected to Show Video Info Shows features of the video signal The numerical keys can be used to switch between th...

Page 106: ...ult Ctrl Backspace to activate the setup mode If the hotkey delay is active press the key combination for seven seconds 2 Press the setup key listed below to reset the default settings D resets the de...

Page 107: ...lation is applied For this purpose the computer is provided with a USB HID Human Interface Device If a special characteristic of your operating environment requires the USB HID emu lation to be perman...

Page 108: ...e and user module This might affect the performance of the FIBREVision sys tem Activate the low or high noise filter level if you experience performance losses This way the colour values are adjusted...

Page 109: ...combi nation for seven seconds 2 Press one of the setup keys listed below to activate a noise filter level Y deactivated noise filter level default X low noise filter level C high noise filter level...

Page 110: ...press Enter 3 Use the arrow keys to select the row Set PLL bandwidth and press Enter 4 Optional If you apply a multichannel variant use the arrow keys to move the cursor to the channel whose bandwidth...

Page 111: ...es How to reset the default values of the enhanced configuration settings Setup menu 1 Use the terminal emulator to establish a connection to the FIBREVision sys tem 2 Use the arrow keys to select the...

Page 112: ...GETLOG While the KVM extender is in operation the last 32 events are logged If the buffer for new events is occupied older ones are overwritten with new events New events of the KVM extender can be r...

Page 113: ...ction to monitor Monitor disconnected no cable connection to monitor Remote Unit Offline interrupted connection to user module CON Remote Unit Online established connection to user module CON Screen F...

Page 114: ...emote status of user module CON OK FAIL USBStatus Mode TRANS status of transparent USB bus OK FAIL NOTE Only KVM extenders with USB 1 1 support monitor the status of the trans parent USB bus For devic...

Page 115: ...3 FirmwareLocal 1 2 3 FirmwareLocal FirmwareRemote 1 2 3 FirmwareRemote MonitorManufacturer Samsung MonitorManufacturer MonitorModel Syncmaster MonitorModel MonitorSerial H9XP4711123 MonitorSerial INV...

Page 116: ...r example provide a free space of at least 7 9 mm equals the height of the device stands Device sides at least 5 cm Device top side at least 3 cm Device bottom side at least 7 9 mm equals the height o...

Page 117: ...erface according to the DVI specification 1 0 This restriction mainly affects the pixel rate which can reach from 25 MHz to 165 MHz Therefore resolutions between 640 x 480 pixels at 60 Hz and 1600 120...

Page 118: ...NOTE While generating the video signal some graphics cards differentiate between digital and analog output Such graphics cards generate digitally output image signals with partly non standardised tim...

Page 119: ...for the power supply is turned off or the connection of the device with the mains supply is not established Check the connection of the IEC cable Red on The optional power pack is connected and provi...

Page 120: ...Sys on System ready for operation slow blinking Defective internal communication Restart the device blinking Activated setup mode fast blinking The temperature in the device exceeds the valid values...

Page 121: ...or connecting a panel to the user module 2 x two pin connection cable 0 4 metres 2 x two pin extension cable 0 4 metres Functionality The remote control of both ATX Power and Reset function is carried...

Page 122: ...is not long enough it can be extended with one of the extension cables Pwr MB Connect the pins you have written down before with the plug position of the ATX Power button on the motherboard Use one o...

Page 123: ...n The functions of the panel buttons correspond to the functions of both the ATX Power button and the Reset button at the computer casing Figure 8 Interface Power Card at the computer module FIBREVisi...

Page 124: ...lustrates how the pins are assigned to the panel s functions To switch one of the ATX Power or Reset signals the signal has to be conductively connected to the shared minus contact pin 4 Figure 10 Pin...

Page 125: ...nsole Monitor see specific features PS 2 keyboard mouse 2 PS 2 socket USB keyboard mouse 2 USB A socket Audio variants AR and ARU 3 5 mm jack plug Speaker 3 5 mm jack plug Micro In USB 1 1 variants AR...

Page 126: ...ts AR and ARU Transmission type transparent Transmission rate max 115 200 bit s Supported signals RxD TxD RTS CTS DTR DSR DCD Update Mode local service socket Interface 1 USB mini B socket Main power...

Page 127: ...nsions W H D 210 44 210 mm Desktop 19 1 HU 210 mm Rackmount Weight approx 1 3 kg Operating environment Temperature 5 to 45 C Air humidity 20 80 non condensing FIBREVISION CON Interfaces for remote con...

Page 128: ...ng Material anodised aluminium Dimensions W H D 435 44 210 mm Weight approx 3 1 kg Operating environment Temperature 5 to 40 C Air humidity 20 80 non condensing FIBREVISION MC2 CON Interfaces for remo...

Page 129: ...ottom Dimensions W H D 435 44 285 mm Weight approx 3 4 kg Operating environment Temperature 5 to 35 C Air humidity 20 80 non condensing FIBREVISION MC4 CON Interfaces for remote console Monitor 4 DVI...

Page 130: ...es fibreswith200MHz km Performance data Wave length 850 nm 770 nm to 860 nm Optical poweroutput PAVG in 50or62 5 mMMF 9 5 dBm to 3 dBm Receivingsensitivity PMIN 17 dBm Sensitivity Stressed PS 13 5 dBm...

Page 131: ...U CPU 100 240V 60 50Hz 0 5 0 2A 22W 100VAC 22W 240VAC MC2 U CON 100 240V 60 50Hz 0 6 0 3A 32W 100VAC 32W 240VAC MC2 AR CPU 100 240V 60 50Hz 0 5 0 2A 22W 100VAC 22W 240VAC MC2 AR CON 100 240V 60 50Hz...

Page 132: ...2 0A 22W 12VDC MC2 CPU 12VDC 1 7A 18W 12VDC MC2 CON 12VDC 1 5A 16W 12VDC MC2 U CPU 12VDC 1 7A 18W 12VDC MC2 U CON 12VDC 2 4A 26W 12VDC MC2 AR CPU 12VDC 1 7A 18W 12VDC MC2 AR CON 12VDC 1 5A 17W 12VDC...