General information
Component parts and accessories
1.
Main
unit
2.
Installation
accessories
•
Installation
instructions
•
WiFi module including 20 m extension cable
•
Installation plate for WiFi module
•
Union
couplings
•
Damping rubber blocks
•
Winter
cover
Important information
Transport and storage
Models designed to be transported vertically must be
transported in this way. This is because the suspension inside
the compressor can be damaged if the unit is laid down. If
the heat pump is tilted during installation or draining this
should be done with care and for the shortest time possible.
The original packaging is intended to be used to reduce the
risk of transport damage.
Remove the packaging and before installation check that the
heat pump has not been damaged during transport. Report
any transport damage immediately upon receipt to the
forwarding agent.
Installation
The pool heat pump must be installed by a qualified
installation engineer and placed outdoors. The unit must
stand firmly, straight and raised from ground level. Provide a
firm and flat surface, for example, a ground stand, a garden
slab, concrete bed, Leca blocks or similar. Note that the
wooden pallet that the pool pump is resting on for delivery is
to be removed during installation.
Noise propagation must be taken into consideration when
positioning during installation. Positioning of the unit must
be done so that noise from the compressor and fan disturb
the environment as little as possible.
Large amounts of melt and condensation water can be
discharged during defrosting and operation. Consequently, it
is important to provide good drainage and run-off.
The units must stand freely so that air is not prevented to
pass the evaporator. Avoid a placement that produces cold
air circulation as this reduces the output of the heat pump.
Use and operation
The parameters on the display are set at the factory and do
not need to be adjusted. The temperature is set to 27 °C. If
you wish to increase the temperature, check first to ensure
that your wishes of a high temperature do not contravene
any guarantees concerning the general pool construction.
Maintenance procedures
It is important to drain the pool heat pump of water in
connection with the winter mothballing of your swimming
pool. Note that a materials warranty is not covered by freeze
damage resulting from the lack of maintenance or handling
errors. The heat exchanger can also be flushed out to remove
any remaining deposits when draining. Read more about
drainage in section 4 - Maintenance, service and fault tracing.
Perform regular checks to ensure that the inlet grille is not
blocked by leaves, snow, etc. In addition, make sure that
excessive frost or ice does not build up below the unit during
cold weather conditions. Read more about maintenance in
section 4 – Maintenance, service and fault tracing.
The outer case can be cleaned using a damp cloth if
necessary. Take care not to scratch the unit. To minimize
ageing of the surface, it’s recommended to apply wax at least
once every year.
Service and support
The pool heat pumps are designed for reliable operation and
a long life. If an error should occur you should always contact
the installation engineer who carried out the installation. If
the installation engineer in turn considers it to be a question
of a material or manufacturing fault, he will contact us for
inspection and action to rectify the problem. Always state
the product’s serial number. This number can be found under
the rating plate on the short side of the unit. A basic guide to
fault tracing is presented in section 4 - Maintenance, service
and fault tracing.
Miscellaneous
The unit may only be repaired by a qualified installation
engineer or an accredited workshop. Original spare parts
must be used for repairs.
It is possible to combine solar panels with your pool heat
pump. However, it is important to avoid connecting the hot
solar panel water directly to the pool heat pump. If the solar
panel water becomes too hot you risk damaging the heat
pump beyond repair.
Installation material is enclosed outside the
machine. Note that the installation engineer
provides pipes and the bypass coupling for the
installation.
!