12
8.1 Do not use instruments other than the provided wrench to install,
disassemble or pre-bent Gutta Percha Injecting Needle.
8.2 Do not knock or scratch the Hot Melting and Filling Instrument.
8.3 Keep heat carrier accessories such as Hot Melting and Filling
Instrument, Gutta Percha Injecting Needle, Thermal Protector Cap etc.
under heating state away from inflammable and explosive materials.
8.4 Please keep the device clean before and after operation. Before each
use, please clean, disinfect and sterilize the accessories such as Gutta
Percha Injecting Needle, Thermal Protector Cap and wrench.
8.5 The product should be in strict accordance with relevant operation
specifications of medical authority and relative regulations. The product
can only be operated by trained doctors or technicians.
8.6 Do not install, remove, or replace the Thermal Protector Cap and
needle under heating state. If you need to replace the needle, please first
power off and wait for 5 minutes. Five minutes later, if the Hot Melting
and Filling Instrument totally cools down, replace the needle.
8.7 The needle must be correctly installed to prevent from falling off or
gutta-percha leakage during operation.
8.8 Do not use excessive force when pre-bending the injection needle to
prevent the needle from breaking. When the needle is bent or worn, the
gutta-percha flowing ability may be deteriorated, and the operator should
replace the new needle in time according to the clinical condition.
8.9 If the device is not in use for a long time, please remove the battery.
8.10 If the device is abnormal , cannot be shut down normally , or needs
an emergency stop, please unplug the battery.
8.11 Do not place the device where it is difficult to operate the disconnect
device.
8.12 Woodpecker is specialized in producing medical instrument.We are
only responsible for the safety on the following conditions:
a) The maintenance, repair, and modification are made by the manufacturer
or the authorized dealers.
b) The charged components are original of “Woodpecker” and operated
according to instruction manual.
9 Cleaning,Disinfection,Sterilization and Maintenance
The cleaning, disinfection and sterilization of Gutta Percha Injecting
Needle.Unless otherwise stated, it will be hereinafter referred to as
“product”.
Warnings:
The use of strong detergent and disinfectant (alkaline pH>9 or acid pH <5)
will reduce the life span of product. And in such cases, the manufacturer
takes no responsibility. This product shall not be exposed to high temperature
above 138°C.