RadaScan
Operator - 15
Reflection Property page
This area of the RadaScan User Console screen provides detailed information
on a number of different topics. The property sheet uses tabbed pages to
group information and has four tabs:
Reflections page
- Provides a numeric list of the reflections received during the
last complete revolution of the sensor rotor. This page can be used to verify the
graphical representation of reflections shown within the Sensor display.
As a new revolution is started, the list is cleared and starts again. For each
verified reflection the list provides: Target ID code, Range, Bearing and Signal
to Noise Ratio. The latter relates to the quality of the reflection. For changes up
to 200m this value will ideally be between 13 and 21.
Radascan Operators Manual 20/11/06 1:46 pm Page 15