Specifications
epc8041CPUSensorVsystem
.85.1.5.14.1.0
Gauge32
RO
System Voltage on CPU Board
epc8041CPUSensorVaux
.85.1.5.14.2.0
Gauge32
RO
Auxiliary Voltage on CPU Board
epc8041CPUSensorVmain
.85.1.5.14.3.0
Gauge32
RO
Main Voltage on CPU Board
epc8041CPUSensorTcpu
.85.1.5.14.4.0
Integer32
RO
Temperature on CPU Board
epc8041NTPTimeValid
.85.1.5.15.1.0
INTEGER
RO
Show if valid Time is received
epc8041NTPUnixTime
.85.1.5.15.2.0
Unsigned32
RO
show received NTP time as unixtime (secs since 1 January 1970)
epc8041NTPLastValidTimestamp
.85.1.5.15.3.0
Unsigned32
RO
show seconds since last valid NTP timestamp received
epc8041RCMBInfoIndex
.85.1.5.16.1.1.x
Integer32
RO
Index of RCMB Info entries
epc8041ResidualCurrentRMS
.85.1.5.16.1.2.x
Unsigned32
RO
Actual Residual Current RMS on Pow er Channel. According Type B IEC
60755. Only visible on models that support this feature.
epc8041ResidualCurrentDC
.85.1.5.16.1.3.x
Unsigned32
RO
Actual Residual Current DC on Pow er Channel. According Type B IEC
60755. Only visible on models that support this feature.
epc8041RCMBOutputRMS
.85.1.5.16.1.4.x
INTEGER
RO
show s the output S1 of the RCMB module
epc8041RCMBOutputDC
.85.1.5.16.1.5.x
INTEGER
RO
show s the output S2 of the RCMB module
epc8041RCMBModuleStatus
.85.1.5.16.1.6.x
Unsigned32
RO
RCMB Module Status Word
epc8041SensorIndex
.85.1.6.1.1.1.x
Integer32
RO
None
epc8041TempSensor
.85.1.6.1.1.2.x
Integer32
RO
actual temperature
epc8041HygroSensor
.85.1.6.1.1.3.x
Integer32
RO
actual humidity
epc8041AirPressure
.85.1.6.1.1.5.x
Integer32
RO
actual air pressure
epc8041Dew Point
.85.1.6.1.1.6.x
Integer32
RO
dew point for actual temperature and humidity
epc8041Dew PointDiff
.85.1.6.1.1.7.x
Integer32
RO
difference betw een dew point and actual temperature (Temp -
Dew Point)
epc8041ExtSensorName
.85.1.6.1.1.32.x
OCTETS
RW
A textual string containing name of a external Sensor
4.6.2
Device MIB 8045
Below is a table of all device-specific OID 's which can be accessed via SNMP. In the
numerical representation of the OID the prefix " 1.3.6.1.4.1.28507 " (Gude Enterprise
OID) was omitted at each entry in the table to preserve space. The example for a com-
plete OID would be "1.3.6.1.4.1.28507.87.1.1.1.1". A distinction is made in SNMP OID 's
in between tables and scalars. OID scalar have the extension ".0" and only specify a
value. In SNMP tables the "x" is replaced by an index (1 or greater) to address a value
from the table.
Name
OID
Type
Acc.
Description
epc8045TrapCtrl
.87.1.1.1.1.0
Integer32
RW
0 = off 1 = Ver. 1 2 = Ver. 2c 3 = Ver. 3
epc8045TrapIPIndex
.87.1.1.1.2.1.1.x
Integer32
RO
A unique value, greater than zero, for each receiver slot.
Summary of Contents for Expert Power Control 8041 Series
Page 2: ...2 Expert Power Control 8041 8045 2022 GUDESystems GmbH ...
Page 5: ...Device Description ...
Page 14: ...Operating ...
Page 25: ...Configuration ...
Page 54: ...Specifications ...
Page 112: ...Support ...