Guardian ULTRA SOURCE 004451 Owner'S Manual Download Page 32

30

Section 7 — Exploded Views and Parts Lists

Commercial-Industrial-Residential Portable Generator System

Control Panel – Drawing No. 0E0227B

2.2 CORD SETS AND CONNECTION 

PLUGS

2.2.1 AC, 20 AMP, DUPLEX RECEPTACLE

This is a 120 Volt outlet protected against overload by a 20 Amp

push-to-reset circuit breaker. Use each socket to power 120 Volt AC,

single phase, 60 Hz electrical loads requiring up to a combined 2400

watts (2.4 kW) or 20 Amps of current. Use only high quality, well-

insulated, 3-wire grounded cord sets rated for 125 Volts at 20 Amps

(or greater).

Keep extension cords as short as possible, preferably less than 15

feet long, to prevent voltage drop and possible overheating of wires.

Figure 7 - 120 Volt AC, 20 Amp, Duplex Receptacle

2.2.2 120V AC, 20 AMP, GFCI RECEPTACLE

This unit is equipped with a ground fault circuit interrupter (GFCI).

This device meets applicable federal, state and local codes.

A GFCI receptacle is different from conventional receptacles. In

the event of a ground fault, a GFCI will trip and quickly stop the

flow of electricity to prevent serious injury.

Definition: Instead of following its normal safe path, electricity

passes through a persons body to reach the ground. For example,

a defective appliance can cause a ground fault.

A GFCI receptacle does NOT protect against circuit overloads,

short circuits, or shocks. For example, electric shock can still

occur if a person touches charged electrical wires while standing

on a non-conducting surface, such as a wood floor.

Figure 8 - 120 VAC, 20 Amp GFCI Receptacle

Testing the GFCI:  Test the GFCI outlet every month as follows:
•  Plug a test lamp into the receptacle.
•  Start the generator, the test lamp should be on.
•  Press the “Test” button located on the front of the receptacle

to trip the device.

•  This should stop the flow of electricity making the lamp shut

off.  The yellow trip indicator should now be on.

•  To restore the flow of electricity, press the “Reset” button on

the front of the receptacle.  If the GFCI does not perform in this

manner, do not use the receptacle. Contact a local service

dealer.

•  This outlet is protected against overload by a 20A push-to-

reset circuit breaker.  Use the outlet to power 120V AC, single-

phase, 60 Hz, electrical loads requiring up to a combined 2400

watts (2.4 kW) or 20 amps of current.

2.2.3 120V AC, 30 AMP RECEPTACLE

Use a NEMA L5-30 plug with this receptacle. Connect a 3-wire

cord set rated for 125 Volts AC at 30 Amps (or greater) to the

plug.

7

Section 2 – Operation

Commercial-Industrial-Residential Portable Generator System

54

5

1

2

15

14

13

59

6

59

42

41

12

42

41

11

42

59

41

10

46

8

9

41

42

43

38

39

40

8

44

18

17

45

16

18

17

19

20

47,48

28

41

33

42

7

31

30

32

9

8

49

36

37

34

35

29

27

17

18

18

22

17

26

25

51

9

8

64

4

21

4

50

53

5

7

56

52

61

24

58

55

60

62

3

63

23

Summary of Contents for ULTRA SOURCE 004451

Page 1: ...Y ASSEMBLY OPERATION TROUBLESHOOTING ELECTRICAL DATA PARTS WARRANTY 1 800 333 1322 ULTRA SOURCE Portable Generator COMMERCIAL INDUSTRIAL RESIDENTIAL MODELS 004451 12 500 WATT 004582 15 000 WATT AUTHOR...

Page 2: ......

Page 3: ...rate the equipment in an emergency CAUTION Always disconnect spark plug wire and place the wire where it cannot contact the spark plug to prevent accidental starting when setting up transporting adjus...

Page 4: ......

Page 5: ...lations Adhere strictly to local state and national electrical and building codes Comply with regulations the Occupational Safety and Health Administration OSHA has established Also ensure that the ge...

Page 6: ......

Page 7: ...rminal After making sure that the connection is tight slip the rubber boot over the terminal connection Connect the BLACK battery cable to the battery Negative terminal Make sure the connection is tig...

Page 8: ......

Page 9: ...cause a ground fault A GFCI receptacle does NOT protect against circuit overloads short circuits or shocks For example electric shock can still occur if a person touches charged electrical wires whil...

Page 10: ......

Page 11: ...e time This total should not be greater than a the rated wattage amperage capacity of the generator or b circuit breaker rating of the receptacle supplying the power See Don t Overload the Generator b...

Page 12: ......

Page 13: ...ge Alcohol blended fuels called gasohol ethanol or methanol can attract moisture which leads to separation and formation of acids during storage Acidic gas can damage the fuel system of an engine whil...

Page 14: ......

Page 15: ...o recharge 12 Volt batteries proceed as follows Check fluid level in all battery cells If necessary add ONLY distilled water to cover separators in battery cells Do not use tap water If the battery is...

Page 16: ......

Page 17: ...ngs 3 3 2 TO CLEAN THE GENERATOR Use a damp cloth to wipe exterior surfaces clean A soft bristle brush may be used to loosen caked on dirt oil etc A vacuum cleaner may be used to pick up loose dirt an...

Page 18: ......

Page 19: ...the engine While watching the piston through the spark plug hole The piston should move up and down The piston is at TDC when it is up as high as it can go Loosen the rocker jam nut Use an 10mm allen...

Page 20: ......

Page 21: ...king 7 Put choke knob to No Choke position 8 Low oil level 8 Fill crankcase to proper level 9 Excessive rich fuel mixture 9 Contact Authorized Service Facility 10 Intake valve stuck open or closed 10...

Page 22: ......

Page 23: ...21 Section 5 Notes Commercial Industrial Residential Portable Generator System...

Page 24: ......

Page 25: ...23 Section 6 Electrical Data Commercial Industrial Residential Portable Generator System Schematic Drawing No 0E0229 A...

Page 26: ......

Page 27: ...ING OIL CLR 35 0E9842 1 SEAL 42 I D CRANKSHAFT ITEM PART NO QTY DESCRIPTION 36 0C5731 1 ASSEMBLY HOUSING COVER WITH SLEEVE 37 0C3006 10 SCREW HHFC M10 1 5 X 55 38 080318 8 SCREW HHFC M6 1 0 X 25 39 0C...

Page 28: ......

Page 29: ...EW TAPTITE M6 1 0 X 25 BP ITEM PART NO QTY DESCRIPTION 115 0F1338B 1 ASSY IGN COIL W DIODE NO ADV 116 0C4147 1 PUMP IMPULSE 117 022264 2 WASHER LOCK M4 118 0D6142 2 SCREW PPHM M4 0 7 X 40 119 0D5399A...

Page 30: ......

Page 31: ...SCREW TAP R 10 32 X 9 16 ITEM PART NO QTY DESCRIPTION 23 0A2038 1 WASHER FLAT 3 8 ZINC 24 022237 5 WASHER LOCK 3 8 25 022511 4 SCREW HHC 3 8 16 X 1 1 4 G5 26 022131 4 WASHER FLAT 3 8 M10 ZINC 27 0517...

Page 32: ......

Page 33: ...20 ITEM PART NO QTY DESCRIPTION 32 022158 1 NUT HEX 10 32 33 023897 1 WASHER FLAT 10 34 057405 1 RESISTOR 25R 5 25W 35 022473 1 WASHER FLAT 1 4 36 022097 1 WASHER LOCK M6 1 4 37 049813 1 NUT HEX M6 1...

Page 34: ......

Page 35: ...39214 6 BOLT CARR 3 8 16 X 1 28 0D9165 1 AXLE 3 4 DIA X 30 15 kW 0D2496 1 AXLE 3 4 DIA X 27 25 12 5 kW ITEM PART NO QTY DESCRIPTION 29 045900 2 WASHER FLAT 3 4 15 kW 045900 4 WASHER FLAT 3 4 12 5 kW 3...

Page 36: ......

Page 37: ...emissions related part repaired or replaced under the ECS warranty shall be warranted for the remainder of the ECS Warranty Period prior to the first scheduled replacement point for such emissions rel...

Page 38: ......

Page 39: ......

Page 40: ......

Reviews: