Guardian ULTRA SOURCE 004451 Owner'S Manual Download Page 31

Figure 9 - 120 VAC, 30 Amp Receptacle

Use this receptacle to operate 120 Volt AC, 60 Hz, single phase

loads requiring up to 3600 watts (3.6 kW) of power at 30 Amps.

The outlet is protected by a 30 Amp push-to-reset circuit breaker.

2.2.4 120/240V AC, 30 AMP RECEPTACLE

Use a NEMA L14-30 plug with this receptacle. Connect a suitable

4-wire grounded cord set to the plug and to the desired load. The

cord set should be rated for 250 Volts AC at 30 Amps (or greater).

Figure 10 - 120/240 VAC, 30 Amp Receptacle

Use this receptacle to operate 120 Volt AC, 60 Hz, single phase

loads requiring up to 3600 watts (3.6 kW) of power at 30 Amps

or 240 Volt AC, 60 Hz, single phase loads requiring up to 7200

watts (7.2 kW) of power at 30 Amps. The outlet is protected by

two  30 Amp push-to-reset circuit breakers.

2.2.5 12 VOLT DC, 10 AMP RECEPTACLE

This receptacle allows you to recharge a 12 Volt automotive or

utility style storage battery with the battery charge cables

provided. This receptacle 

can not

recharge 6 Volt batteries and

can not

be used to crank an engine having a discharged battery.

See the section "Charging a Battery" (page 12) before attempting

to recharge a battery.

Figure 11 - 12 Volt DC, 10 Amp Receptacle

2.2.6 120/240 VOLT AC, 50 AMP
RECEPTACLE

Use a NEMA 14-50 plug with this receptacle.  Connect a 4-wire

cord set rated for 250 Volts AC at 50 Amps to the plug.

Figure 12 - 120/240 VAC, 50 Amp Receptacle

Use this receptacle to operate 120/240 Volt AC, 60 Hz electrical

loads requiring up to 12,000 watts (12.0 kW) of power.  This

receptacle is protected by a 50 Amp 2-pole circuit breaker.

8

Section 2 – Operation

Commercial-Industrial-Residential Portable Generator System

29

ITEM PART NO.

QTY. DESCRIPTION

1

0C6934

1

ADAPTOR, ENGINE

2

0D2123

1

STATOR 12.5KW

0D2134

STATOR 15KW

0D2136

STATOR 18KW

3

0D21320SRV 1

ASSEMBLY, ROTOR WITH FAN 
12.5KW 

0D21330SRV

ASSEMBLY, ROTOR WITH FAN 
15KW

0D2135

ROTOR 18KW

4

0C6043B

1

CARRIER, REAR BEARING

5

0D2492

1

EXHAUST MANIFOLD

6

0D2726

1

MUFFLER

7

0C4138

2

GASKET, EXHAUST

8

0D3547

1

COVER, ALTERNATOR AIR IN

9

031971

1

BEARING 

10

0C3168

3

5/16 SPECIAL LOCK WASHER

11

0D1838

1

SCREW IHHC 3/8-24 X 15.50 G5

12

0D3549

4

SCREW IHHC M8-1.25 X 400 G8.8

13

0C7038E

1

BRACKET, ALT MOUNTING

14

032712

4

SCREW  HHTT #10-32 X 1.75

15

0D4662

1

SCREW HHTT M8-1.2 X 20

16

0C7038D

1

ENGINE MOUNTING PLATE

17

0C7758

6

RUBBER MOUNT

18

0388050AF0 1

BATTERY CABLE, BLACK

19

0C2417A

1

EARTH STRAP 3/8X 3/8

20

082121C

1

CLIP-J VINYL COAT .625 ID

21

066386

1

ASSEMBLY, BRUSH HOLDER

22

0C2824

1

SCREW TAP-R #10-32 X 9/16

ITEM PART NO.

QTY. DESCRIPTION

23

0A2038

1

WASHER FLAT 3/8 ZINC

24

022237

5

WASHER LOCK 3/8

25

022511

4

SCREW HHC 3/8-16 X 1-1/4 G5

26

022131

4

WASHER FLAT 3/8-M10 ZINC

27

051731

4

SCREW HHC M8-1.25 X 50 G8.8

28

022145

21

WASHER FLAT 5/16 ZINC

29

049820

4

NUT LOCK HEX M8-1.25 NYLON 
INSERT

30

079246

5

SCREW HHC M6-1.0 X 16 WITH 
LOCK WASHER

31

022129

18

WASHER LOCK M8-5/16

32

022259

12

NUT HEX 5/16-18 STEEL

33

059637

2

SCREW TAPTITE 3/8-16 X 3/4 BP

34

0D5100

1

SHIELD, MUFFLER HEAT

35

0D5823

1

U-BOLT & SADDLE

36

0C8565

4

SCREW SHC M8-1.25 X 18

37

0D5833

1

PANEL, MUFFLER BOX BACK

38

0D5834

1

PANEL, MUFFLER BOX END

39

090388

3

SCREW HHTT M6-1.0 X 12

40

022473

5

WASHER FLAT 1/4

41

N/A

-

NOT USED

42

0D5133

1

SPARK ARRESTOR SCREEN

43

0D5133A

1

RETAINER, SPARK ARREST 
SCREEN

44

045764

1

SCREW HHTT M4-0.7 X 8

45

0D6214

1

SHIELD, RUBBER MOUNT

46

066849

2

SCREW HHTT M5-0.8 X 16

Section 7 — Exploded Views and Parts Lists

Commercial-Industrial-Residential Portable Generator System

Generator – Drawing No. 0D4488-D

Summary of Contents for ULTRA SOURCE 004451

Page 1: ...Y ASSEMBLY OPERATION TROUBLESHOOTING ELECTRICAL DATA PARTS WARRANTY 1 800 333 1322 ULTRA SOURCE Portable Generator COMMERCIAL INDUSTRIAL RESIDENTIAL MODELS 004451 12 500 WATT 004582 15 000 WATT AUTHOR...

Page 2: ......

Page 3: ...rate the equipment in an emergency CAUTION Always disconnect spark plug wire and place the wire where it cannot contact the spark plug to prevent accidental starting when setting up transporting adjus...

Page 4: ......

Page 5: ...lations Adhere strictly to local state and national electrical and building codes Comply with regulations the Occupational Safety and Health Administration OSHA has established Also ensure that the ge...

Page 6: ......

Page 7: ...rminal After making sure that the connection is tight slip the rubber boot over the terminal connection Connect the BLACK battery cable to the battery Negative terminal Make sure the connection is tig...

Page 8: ......

Page 9: ...cause a ground fault A GFCI receptacle does NOT protect against circuit overloads short circuits or shocks For example electric shock can still occur if a person touches charged electrical wires whil...

Page 10: ......

Page 11: ...e time This total should not be greater than a the rated wattage amperage capacity of the generator or b circuit breaker rating of the receptacle supplying the power See Don t Overload the Generator b...

Page 12: ......

Page 13: ...ge Alcohol blended fuels called gasohol ethanol or methanol can attract moisture which leads to separation and formation of acids during storage Acidic gas can damage the fuel system of an engine whil...

Page 14: ......

Page 15: ...o recharge 12 Volt batteries proceed as follows Check fluid level in all battery cells If necessary add ONLY distilled water to cover separators in battery cells Do not use tap water If the battery is...

Page 16: ......

Page 17: ...ngs 3 3 2 TO CLEAN THE GENERATOR Use a damp cloth to wipe exterior surfaces clean A soft bristle brush may be used to loosen caked on dirt oil etc A vacuum cleaner may be used to pick up loose dirt an...

Page 18: ......

Page 19: ...the engine While watching the piston through the spark plug hole The piston should move up and down The piston is at TDC when it is up as high as it can go Loosen the rocker jam nut Use an 10mm allen...

Page 20: ......

Page 21: ...king 7 Put choke knob to No Choke position 8 Low oil level 8 Fill crankcase to proper level 9 Excessive rich fuel mixture 9 Contact Authorized Service Facility 10 Intake valve stuck open or closed 10...

Page 22: ......

Page 23: ...21 Section 5 Notes Commercial Industrial Residential Portable Generator System...

Page 24: ......

Page 25: ...23 Section 6 Electrical Data Commercial Industrial Residential Portable Generator System Schematic Drawing No 0E0229 A...

Page 26: ......

Page 27: ...ING OIL CLR 35 0E9842 1 SEAL 42 I D CRANKSHAFT ITEM PART NO QTY DESCRIPTION 36 0C5731 1 ASSEMBLY HOUSING COVER WITH SLEEVE 37 0C3006 10 SCREW HHFC M10 1 5 X 55 38 080318 8 SCREW HHFC M6 1 0 X 25 39 0C...

Page 28: ......

Page 29: ...EW TAPTITE M6 1 0 X 25 BP ITEM PART NO QTY DESCRIPTION 115 0F1338B 1 ASSY IGN COIL W DIODE NO ADV 116 0C4147 1 PUMP IMPULSE 117 022264 2 WASHER LOCK M4 118 0D6142 2 SCREW PPHM M4 0 7 X 40 119 0D5399A...

Page 30: ......

Page 31: ...SCREW TAP R 10 32 X 9 16 ITEM PART NO QTY DESCRIPTION 23 0A2038 1 WASHER FLAT 3 8 ZINC 24 022237 5 WASHER LOCK 3 8 25 022511 4 SCREW HHC 3 8 16 X 1 1 4 G5 26 022131 4 WASHER FLAT 3 8 M10 ZINC 27 0517...

Page 32: ......

Page 33: ...20 ITEM PART NO QTY DESCRIPTION 32 022158 1 NUT HEX 10 32 33 023897 1 WASHER FLAT 10 34 057405 1 RESISTOR 25R 5 25W 35 022473 1 WASHER FLAT 1 4 36 022097 1 WASHER LOCK M6 1 4 37 049813 1 NUT HEX M6 1...

Page 34: ......

Page 35: ...39214 6 BOLT CARR 3 8 16 X 1 28 0D9165 1 AXLE 3 4 DIA X 30 15 kW 0D2496 1 AXLE 3 4 DIA X 27 25 12 5 kW ITEM PART NO QTY DESCRIPTION 29 045900 2 WASHER FLAT 3 4 15 kW 045900 4 WASHER FLAT 3 4 12 5 kW 3...

Page 36: ......

Page 37: ...emissions related part repaired or replaced under the ECS warranty shall be warranted for the remainder of the ECS Warranty Period prior to the first scheduled replacement point for such emissions rel...

Page 38: ......

Page 39: ......

Page 40: ......

Reviews: