background image

E-8

E-9

REPLACING THE UV-C BULB

TROUBLE SHOOTING GUIDE

Water vapor and humidity 

are not produced.

Power Plug: Unplug and then try again.

Power Failure: When the power is returned, try again.

Tank Installation: Make sure the tank is correctly attached.

The surface of the ultrasonic disk is dirty: Clean ultrasonic disk. (see pg. E-7)

PROBLEM

SOLUTION

Air blows but water vapor 

is not produced.

Excessive Water: Remove a certain amount of water from the tank. 

Increase mist setting.

Detergent residue and/or oil ingredients from cosmetics may be in tank; 

wash out tank and try again.

The surface of the ultrasonic disk is dirty: Clean ultrasonic disk. 

(see pg. E-7) If you use hard water, replace with softer water.

Humidity level is low.

The surface of the ultrasonic disk is dirty: Clean ultrasonic disk. (see pg. E-7) 

The water in the unit is too cold: Replace with cool, but not cold water. 

Damage on the ultrasonic disk: Contact Customer Service

The humidity has 

a bad smell.

Poor maintenance or dirty water: Clean the product thoroughly, 

and fill it with fresh water.

White dust is forming on

nearby furniture.

Hard water may deposit a certain amount of dust. Dust in the air also 

settles because of added humidity in the room. Use distilled water if 

this becomes a nuisance.

* Decalcification Filter (FLTDC) available at www.guardiantechnologies.com

  or through Customer Service 1.866.603.5900.

Unit has stopped working.

No or low water. Unplug unit and refill tank. Check timer has not been set.

Water is accumulating outside 

of unit or area surrounding unit.

Saturation of humidity. Lower mist control setting.

Unit not level and water is accumulating. Unplug and place on level 

surface. Point spray away from objects. Raise unit on a water-resistant 

level surface 2-3 feet off of floor.

Increased noise level.

Unit must be placed on a flat, level, hard surface. 

Make sure it is NOT placed on a soft or absorbent surface.

Warm humidity is not produced. It may take 10-15 minutes before warm humidity is created. The mist

may not feel warm due to the fact it is so fine and is cooled rather

quickly from the air in your home. Test by either feeling the base of the

unit which should be warm to the touch or by allowing the unit to run for

approximately 30 minutes on warm setting in a closed 200 sq. foot room

or smaller. The room should feel moderately warmer if the unit is

working properly.

Unit shuts off unexpectedly or 

does not operate.

Check that the safety device triggered. To restart, unplug for 5 sec/replug

then press the power button. Call Customer Service.

Water dripping when refilling.

Water remaining on bottom of tank. Wipe tank or tilt to drain before

transporting.

Make sure tank cap is secured tightly.

1. 

Unplug the unit.

2. 

Remove the tank and empty all water

  from the unit base and tank.

3.

 Flip the base over and locate the 

  UV-C Bulb Compartment.

4.

 Remove the two screws using 

  a philips screw driver.

5.

 Remove the lid with connected UV-C Bulb.

6.

 Twist the light bulb to the left until you can remove it.

7.

 Replace with new bulb, insert and turn 

  to the right to secure into place.

8.

 Replace the lid and secure with two screws.

Summary of Contents for H5450

Page 1: ...tilize this warranty according to the conditions stated above To submit product under warranty the complete machine must be delivered pre paid to Guardian Technologies LLC Please include complete info...

Page 2: ...one is home Do not keep water in the tank when not in use for an extended period of time Do not clean the unit water tank or water reservoir with detergents or chemicals of any kind The use of water...

Page 3: ...it to the right It is important to FIRMLY secure cap after filling the tank with water 5 Attach the tank to the base of the unit and plug in 6 POWER BUTTON Before turning on make sure there is water i...

Page 4: ...rface of the unit with a soft damp cloth if needed If you notice an accumulation of water during usage reduce humidity and dry outer surface with a cloth DESCALING Depending on usage and water type cl...

Page 5: ...has not been set Water is accumulating outside of unit or area surrounding unit Saturation of humidity Lower mist control setting Unit not level and water is accumulating Unplug and place on level sur...

Page 6: ...autre aux tats Unis L enregistrement de garantie de l appareil peut se faire en ligne l adresse www guardiantechnologies com Nous consid rons le processus d enregistrement comme important afin d assu...

Page 7: ...prolong e ou lorsque personne n est la maison Ne laissez pas d eau dans le r servoir lorsque vous n utilisez pas l appareil pendant une p riode prolong e Ne nettoyez jamais l appareil ni le r servoir...

Page 8: ...ournant vers la droite Il est important de BIEN serrer le bouchon apr s avoir rempli le r servoir d eau 5 Rattachez le r servoir la base de l appareil et branchez le 6 BOUTON MARCHE ARR T Avant de met...

Page 9: ...rieur de l appareil Essuyez la surface de l appareil l aide d un chiffon doux et humide au besoin Si vous remarquezune accumulation d eau pendant le fonctionnement de l appareil r duisez l humidit et...

Page 10: ...i aucune humidit ne sont mises Prise d alimentation d branchez l appareil et rebranchez le pour r essayer Panne de courant r essayez une fois la panne termin e Installation du r servoir v rifiez que l...

Page 11: ...do en los EE UU Puede completar el registro de la garant a en l nea en www guardiantechnologies com Consideramos que el proceso de registro es importante para garantizar el servicio superior a nuestro...

Page 12: ...aso de que la unidad haya sido colocada de manera incorrecta No lo utilice si el enchufe est da ado o suelto Antes de llenar o limpiar la unidad aseg rese de que est desconectada Una vez que haya cone...

Page 13: ...la tapa despu s de llenar el dep sito con agua 5 Vuelva a colocar el dep sito en la base de la unidad y con ctela 6 BOT N INTERRUPTOR Antes de encender la unidad verifique que la unidad est llena de a...

Page 14: ...illo suave se recomienda usar un cepillo para limpiar botellas Superficie externa de la unidad De ser necesario limpie la superficie externa de la unidad con un pa o suave h medo Si observa acumulaci...

Page 15: ...ad est apareciendo un polvo blanco El agua dura puede crear ciertos dep sitos de polvo El polvo en el aire tambi n se asienta debido a la humedad de la habitaci n Si le molesta este polvo use agua des...