QX User Manual – Issue B
- 16
-
Test
Code-04
Each area of the system can be tested individually or all areas can be tested at the same time. The
test time is limited to 1 hour. If the user does not end the test by the end of the test time then the panel
will exit test mode automatically.
04=Test
Area
Number _
✕
4
✕
Sounder On
1
Enter Area
Number
Audio On
Strobe On
2
3
PIR in Hall
Not Tested
Front Door
Not Tested
Walk Test
All Tested
Untested circuits
will be displayed
Tel Number 1
Please Wait . . .
Tel Number 2
Please Wait . . .
Acknowledge
received
5
All numbers
Tested
0
3=Audio
4=Walk Test
5=Comms Test
1=Sounder
2=Strobe
4
All circuits
tested
✕
✕
✕
The panel records all activations from sensors during the unset period. When walk test is selected the
panel will display all circuits which have not alarmed since the panel was last unset. If all circuits are to
be tested then select walk test, then press the
✗
button and select walk test a second time. When the
panel exits walk test mode, either manually or automatically at the end of the test time then:
1. Any fire sensor still in alarm will give a normal alarm response.
2. Circuits with a 24-hour response, which are still in alarm, will be temporarily bypassed.
3. A warning will be displayed if any PA sensor is still in alarm.
If the comms test is selected then the panel will make a test call to all telephone numbers that have
been programmed for test by the installation engineer.