QX User Manual – Issue B
- 12
-
Setting Faults
If the group cannot set a message will be displayed. This can occur at the start of setting or at the end
of the exit time depending on how your system is set up and when the fault occurs. If a fault occurs
during the exit time the exit tone will change to a warning tone. The external sounder may also have
been programmed by the installation engineer to activate in the event of a failure to set.
Workshop
Seconds Left-005
1=Workshop
2=Office
1
✓
Cannot Set
Cct Fault
PIR in Hall
✔
=Force Set
After the setting fault(s) is displayed the force set
option may be presented (if programmed by the
installation engineer). The force set option will attempt
to automatically bypass all faults. The circuit(s) with
the fault must be programmed to allow bypass.
PIR in Hall
Bypassed
✔
=Set
✓
Intelligent Security & Fire Ltd