12
Preparation
Adjusting and setting the forks
Lockout
Unscrew the black cap labelled “Air” and remove
to reveal the Schrader valve.
Attach a pump with a pressure dial to the
Schrader valve and pump to the recommended
or desired psi.
Do not exceed 205 psi.
To lock out the forks, locate the blue lock out
lever on the side of the fork and turn it clockwise
towards the lock symbol.
Use the chart to set the psi, for the fork, to the
appropriate weight.
You may need to adjust the Preload, which is the resistance the fork gives against your weight.
You can choose to activate the Lockout feature. When Lockout is activated it will use the compression
damping system to effectively stop the fork from working. Lockout is useful when you encounter
prolonged climbs.
Front suspension Air Spring
Pressure
50 - 70 psi
70 - 85 psi
135 + psi
85 - 100 psi
205 psi
100 - 120 psi
<140 LBS
( <63 KG)
Rider weight
Pressure
140 - 160 LBS
( 63 - 72 KG)
200 - 220 LBS
( 90 - 99 KG)
160 - 180 LBS
( 72 - 81 KG)
MAX PSI
180 - 200 LBS
( 81 - 90 KG)