background image

 

27 

8 Specifications                                                                                                         

 

8. 1 Electrical 

Model

 

ZS11

0-1K 

ZS110-

1K-KS 

ZS11

0-2K 

ZS110-

2K-KS 

ZS11

0-3K 

ZS110-

3K-KS 

Rating

 

1KVA/800W 

2KVA/1600W 

3KVA/2400W 

Input system 

Single phase & earth ground 

Rated voltage 

220VAC 

Voltage range 

115VAC~300VAC 

Frequency 

50Hz 

Power factor 

0.99 

Input 

Voltage range of 
bypass 

80±5)VAC

~(

286±5)VAC

 

Output system 

Single phase & earth ground 

Rated voltage 

220VAC 

Power factor 

0.8 

Voltage precision 

±

2% 

Normal 
mode 

Output 
frequency 

Battery 
mode 

1.The output frequency synchronizes with the input 

frequency  when  the  input  frequency  is  in  the 
range of 46 Hz

54 Hz 

2.The  output  frequency  is  50Hz  when  the  input 

frequency is not in the range of 46 Hz

54 Hz

 

Inverter overload 
capacity

Utility 

power

25

℃)

 

105%±5%<Load

125%±5% 50s transfer to bypass 

125%±5%< Load <150%±5% 25s transfer to bypass 
Load > 150%±5%,300ms transfer to bypass 

0ms 

Normal mode

←→

  Battery mode

 

Transfer time 

<4ms

Normal mode

←→

Bypass mode

 

Output 

Crest factor 

3:1 

Batteries voltage 

36VDC 

72VDC 

96VDC 

Battery Quantity

 

none 

none 

none 

Battery Type 

Sealed  maintenance-free  lead  –acid  battery  of 
battery voltage 12V/7AH

 

Backup Time

25

℃)

 

Full load

5min (Standard) 

Battery 

Charge current

 

1A 

7A 

1A 

7A 

1A 

7A 

 

28 

8. 2 Mechanical 
 

Model

 

W*H*D(mm)

 

Weight(kg)

 

ZS110-1K 

144×229×350

 

11.5 

ZS110-2K 

190×328×424 

24 

ZS110-3K 

190×328×424

 

28 

ZS110-1K-KS 

144×229×350

 

ZS110-2K-KS 

190×328×424

 

12 

ZS110-3K-KS 

190×328×424

 

12 

 
8. 3 Environmental 

Item

 

Normal range

 

Ambient temperature

 

0

℃~

40

 

Environment humidity 

20%

90%

No condensation

 

Altitude

 

Lower than 1000m: no derating 

Over 1000m :1% derating for every 100m rise 

Storage temperature 

-15

 

45

 

 

 

8. 4 EMC 

Item

 

Standard

 

Level

 

ESD 

IEC61000-4-2 

LEVEL4 

RS 

IEC61000-4-3 

LEVEL3 

EFT 

IEC61000-4-4 

LEVEL4 

Surge 

IEC61000-4-5 

LEVEL4 

 

8. 5 Safety 

Comply with GB4943-2001, IEC62040-1 and CE requirements. 

8. 6 Industry Standard 

Comply with EN62040

YD/T 1095-2000 requirements. 

 

Summary of Contents for ZS110

Page 1: ...1 USER MANUAL On Line UPS Model ZS110 1000VA 2000VA 3000VA Uninterruptible Power Supply System 2...

Page 2: ...Please do not overload the UPS 4 The UPS contains large capacity batteries The case of the UPS must not be opened by untrained personnel Otherwise it may cause electric shock 5 Do not short the posit...

Page 3: ...pe Model Remark 1kVA ZS110 1K With a 1A internal charger and 3 build in batteries of 12V 7AH 2kVA ZS110 2K With a 1A internal charger and 6 build in batteries of 12V 7AH Standard 3kVA ZS110 3K With a...

Page 4: ...to precise regulated sine wave AC power In Battery mode it receives energy from the battery through the DC DC converter 2 Product Description 5 Bypass It is very important in the UPS system In the eve...

Page 5: ...ssary to wait until the UPS fully dried inside out before proceeding to installation and use Otherwise they may be a risk of electric shock 4 Place the UPS near the utility power source outlet which s...

Page 6: ...ng the battery pack 3 Connect the external battery cable to the battery terminal DO NOT connect the battery socket of the UPS first Otherwise it may cause electric shock Connect the red wire to the te...

Page 7: ...connection of communication Intelligent Slot It is designed for installing the dry contact card SNMP card and 485 card You can choose for one of them to installed a dry contact card You can utilize m...

Page 8: ...n Mode UPS Operation Mode contains normal mode battery mode and bypass mode Under the three modes the page showing output voltage and output frequency is the main display page If users need more infor...

Page 9: ...nected one by one l It recommended that the capacity of the generator should double than UPS 18 5 2 2 Battery Mode When operating in the battery mode the display of main page on the front panel is sho...

Page 10: ...percent page actual load page input information page and the maximum temperature page Notes When operating in bypass mode the backup function of the UPS is not available and the power used by the load...

Page 11: ...ly for more than 1 second to 22 power off the UPS If it bas been set up to work in bypass mode by software the bypass indicator will be turned on to indicate that the UPS is working in bypass mode In...

Page 12: ...nt the UPS must be turned off and disconnected from utility power 2 Metal objects such as rings and watches should be removed 3 Use the screwdriver with insulated handle Tools and other metal objects...

Page 13: ...f it does not work Please contact the distributor or service center F09 on constantly Beep continuously The charger of the UPS is defective Please contact the distributor or Service center A01 Blink o...

Page 14: ...er to bypass 0ms Normal mode Battery mode Transfer time 4ms Normal mode Bypass mode Output Crest factor 3 1 Batteries voltage 36VDC 72VDC 96VDC Battery Quantity 3 none 6 none 8 none Battery Type Seale...

Page 15: ...cessories No Machine 1 Intelligent monitor software CD 1 User Manual 1 Standard Model Serial communication cable 1 Machine 1 Intelligent monitor software CD 1 User Manual 1 External Battery Cable 1 Lo...

Reviews: