GT7005EFi
WARNING!
Any connection to a building’s
electrical system: THE GENERATOR
MUST BE ISOLATED FROM MAINS
POWER VIA A TRANSFER SWITCH.
This connection must be made by a
qualified electrician.
NOTE:
The connection of a generating set
bonding system to the general mass of earth
through an earth electrode is not required or
recommended.
Ground Terminal
Earth
Mark
Grounding the Generator
Starting the
Generator
NOTE: Place the generator on a flat, level
surface outdoors and disconnect any load at
the receptacles. Follow all safety and warn-
ing label instructions.
Electric Starting
1. Turn fuel switch to “ON” position and wait
for 30 seconds for fuel to fill the carbureter.
Fuel Switch
ON
OFF
2. Move choke lever to “CLOSED” position.
3. Turn the engine switch to “START” posi-
tion and hold tuntil engine is running
Closed
Choke Lever
Closed
NOTE: When starting, the engine switch
should not stay in the “START” position for
more than 5 seconds.
4. After starting, return switch to “RUN” posi-
tion
5. Once the engine is running, move the
choke lever to the “OPEN” position.
Open
Choke Lever
Open
NOTE: If the engine stops and will not re-
start, check the oil level.
NOTE: Do not move the choke lever to
“CLOSED” position when the engine is hot
or the ambient temperature is high.