background image

5

2.0 - GENERAL CONNECTION DIAGRAM

RED - Pos. 10

BLACK - Pos.  17

RED LED - Pos. 10

RED - Pos. 10

BLACK/RED - Pos. 14

= FUSE TO BE 
   INSERTED

LEGEND:

GREEN/BROWN - Pos. 2

GREEN/BLUE - Pos. 20

BROWN - Pos. 9

ORANGE- Pos. 3

ORANGE - Pos. 4

GREEN/BLACK - Pos. 18

PINK - Pos. 13

GREEN/YELLOW - Pos. 19

POSITIVE OUTPUT

WHEN THE ALARM

IS ARMED 

DOORS LOCK/UNLOCK

SIGNALS SELF-CODING

RAPID TEST

YELLOW/BLACK - Pos. 1

INTERMITTENT

NEGATIVE OUTPUT

IN ALARM

(MAX CAPACITY 100mA

TO ADDITIONAL

SENSORS

INDICATORS

YELLOW - Pos. 21

IGNITION 

SWITCHED LIVE 

+15/54

GREEN - Pos. 7

BONNET/BOOT
PIN SWITCHES

DOORS PIN

SWITCHES

ANTI-HIJACK DOOR

PIN SWITCH

WHITE - Pos. 11

GREY - Pos. 22

ENGINE 

IMMOBILISATION

CUT

PETROL PUMP RELAY

EARTH

RED/BROWN - Pos. 15

RED/GREY - Pos. 5

YELLOW/BROWN - Pos. 16

YELLOW/GREY - Pos. 6

BLUE/VIOLET - Pos. 12

LED/BUTTON

A = NOT AVAILABLE IN THE KIT GT802/3

PO12 V 

(MAX CAPACITY  15 A)

15A

ULTRASONIC

TRANSDUCRES

RED

WHITE

A

COMFORT
NEGATIVE
COMMAND

A

M

P

A

M

P

BLACK/WHITE - Pos. 8

ANTI-HIJACK 
PIN SWITCH

VEHICLE ACTUATORS

SIGNALS

SWITCHES SIGNALS

(DISCRIMINATORS)

LOCK/UNLOCK BUTTON

DOOR SAFETY LOCK

CLOSING ACTUATOR

INDICATORS

8

11

18

21

20

9

6

16

7

10

17

19

22

5

15

3

13 12

4

14

1

2

A

M

P

A

M

P

RED

WHITE

Summary of Contents for GT 800/1

Page 1: ...GT 800 1 2 3 USER AND INSTALLATION MANUAL 1...

Page 2: ...ION OF THE ALARM SYSTEM ARMING DISARMING COMMAND WIRES Page 8 6 0 DOORS LOCK UNLOCK SIGNALS SELF CODING Page 8 7 0 RAPID TEST Page 9 8 0 SELF POWER SUPPLY Page 10 9 0 FINAL OPERATIONS Page 10 10 0 USE...

Page 3: ...switched earth only 8 Connect the GREEN BROWN wire to the existing doors pin switches provided that they are switched earth only 9 If you want to activate the ANTI HIJACK FUNCTION connect the GREEN BL...

Page 4: ...n a position not visible but easily reachable 17 ULTRASONIC SENSOR Install the two ultrasonic transducers at the top of the A pillars one to the right and one to the left see picture pointing towards...

Page 5: ...GNITION SWITCHED LIVE 15 54 GREEN Pos 7 BONNET BOOT PIN SWITCHES DOORS PIN SWITCHES ANTI HIJACK DOOR PIN SWITCH WHITE Pos 11 GREY Pos 22 ENGINE IMMOBILISATION CUT PETROL PUMP RELAY EARTH RED BROWN Pos...

Page 6: ...system if they would be of impulsive type polling 3 3 Memorisation of switches discriminators signals only after actuator signals When you enable or disable this function it is possible to decide if i...

Page 7: ...erates an acoustic signal for each press Before showing the function state the alarm system will generate acoustic signals and the LED BUTTON will flash For example if you wish to check the function s...

Page 8: ...resent when the door lock is being operated by the original vehicle remote WARNING Ensure that the RED BROWN the YELLOW BROWN the RED GREY and the YELLOW GREY wires are correctly connected as indicate...

Page 9: ...trigger the alarm Only the introduction of an object should trigger the alarm 5 If you press the ANTI HIJACK FUNCTION reservation button BLACK WHITE wire you obtain a visual indicators acoustic signal...

Page 10: ...will trigger the alarm system The RAPID TEST procedure can be stopped in two ways A After about 2 minutes from the test function activation the alarm system emits a long acoustic signal and it comes o...

Page 11: ...ng visual and acoustic signal on the indicators or it can be caused by the timer delay circuir of the courtesy light Volumetric protection of the passenger compartment Power supply wires cut only when...

Page 12: ...e LED is illuminated constantly you have 10 seconds to enter your first number of your GT CARD CODE i e if the first number is 2 press the LED button twice 7 After 10 seconds the LED BUTTON will extin...

Page 13: ...ggers circuits are active boot bonnet doors and ignition When the ignition is switched OFF the vehicle will be immobilised and you will not be able to start the vehicle Disarming ANTI HIJACK To disarm...

Page 14: ...ned to our organisation under the terms of the warranty will be replaced or repaired within a reasonable time period according to our Company requirements Any repair refurbishment received within the...

Page 15: ...ion relay contact capacity 15 A 15 Vdc Operating temperature from 40 C to 85 C 5 sec delay time when arming Ignition switched live boot and or bonnet power supply wires cut 60 sec delay time when armi...

Page 16: ...16 InstGT800UKRev00 p65 Getronic S r l Via Calcinate no 12 21026 Gavirate VA Italy Tel 39 0332 756011 Fax 39 0332 731162 www gtalarm it...

Reviews: