Geophysical Survey Systems, Inc.
UtilityScan with GS Software
Manual
MN71-307 Rev B
29
Auto Gain:
With auto gain turned on, the software will configure the
necessary gain values automatically based on where the antenna is
placed. You will want to make sure that the system is setting gains in
an area of representative conditions, but not sitting directly on top of a
feature of interest. If Adaptive Gain and Auto Gain are toggled off,
you will be in Manual Gain mode.
# of Points:
You can set any number of gain points from 1-8. These
will be evenly distributed along the time scale. If 1 gain point is
specified, it will be located at the top of the scan trace.
Current Point #:
This option is only visible if adaptive gain and auto
gain are turned off. If you wish to manually change the gain value
associated with a single point, select that point using this control.
Gain Value:
This option is only visible if adaptive gain and auto gain
are turned off. Changing this will change the amount of gain applied
at the currently selected point. A higher value will increase gain and
brighten the region around that gain point.
Adaptive Gain:
GSSI has developed a gain compensation algorithm
that is designed to more accurately counteract attenuation. This is done by taking the conductivity and
dielectric of the subsurface material into account. This helps accentuate targets with contrasting attributes
from the surrounding material. For example, a clay lens in sand may be much easier to detect with this
gaining method. For best results, specify a reasonably accurate dielectric in the scan menu for the
material.
LineTrac®
The LineTrac menu allows you to turn the LineTrac accessory on or off. This is an additional feature that
is only functional on UtilityScan units that have a LineTrac installed. LineTrac is a sensitive and versatile
locating device that measures the AC current of powered utilities and induced frequencies in non-powered
utilities. Two modes are available: Power Mode, a passive detection mode that tracks AC current in
energized lines; and Frequency Mode, where the device tracks a specific frequency that has been user
induced into a utility line.
Summary of Contents for UtilityScan 50350HS
Page 1: ...MN27 151 Rev A MN71 307 Rev B ...
Page 4: ...Geophysical Survey Systems Inc UtilityScan with GS Software Manual ...
Page 6: ...Geophysical Survey Systems Inc UtilityScan with GS Software Manual ...
Page 8: ...Geophysical Survey Systems Inc UtilityScan with GS Software Manual MN71 307 Rev B 2 ...
Page 14: ...Geophysical Survey Systems Inc UtilityScan with GS Software Manual MN71 307 Rev B 8 ...
Page 20: ...Geophysical Survey Systems Inc UtilityScan with GS Software Manual MN71 307 Rev B 14 1 2 3 4 ...
Page 46: ...Geophysical Survey Systems Inc UtilityScan with GS Software Manual MN71 307 Rev B 40 ...
Page 47: ...Geophysical Survey Systems Inc UtilityScan with GS Software Manual MN71 307 Rev B 41 ...