![GSS STS 1916 IPSR CT CI Assembly Instruction Manual Download Page 14](http://html.mh-extra.com/html/gss/sts-1916-ipsr-ct-ci/sts-1916-ipsr-ct-ci_assembly-instruction-manual_2275535014.webp)
- 14 -
STS 1916 IPSR CT CI
3.3 P
otential
equalisation
(Pe)
Equalise the potential (PE) in accordance with IEC/EN/DIN EN 60728-11.
• Connect the PE connection terminal
17
to a PE rail (supplied by customer)
using the PE wire (Cu 4 mm
2
- 9 mm
2
).
3.4 C
onneCting
the
deviCe
sat i
nPuts
18
HH
HL
VH
VL
4
3
2
1
• Connect the SAT IF inputs 1-4
18
to the
corresponding outputs of an LNB.
•
Make sure that all inputs have the same
level!
—> Factory defaults for ASTRA reception:
Input 4 = horizontal high*; Input 3 = horizontal low*
Input 2 = vertical high*; Input 1 = vertical low*
*Can be changed individually.
—> For multiple satellite reception observe the dCSS/Unicable II mode
Ci
slots
The CI slots are located under the CI cover on the rear of the housing.
• Unscrew 8 screws
22
and remove the cover.
22
—> Note for the selection of slots:
Slots 1…6 are assigned to the tuners 1…6. If a CA module is not
sufficient to descramble all channels of a transponder, alternatively
the modules 6…4 can be assigned to the tuners 1…3 additional:
– Module 1 + 6 for tuner 1,
– Module 2 + 5 for Tuner 2 and
– Module 3 + 4 for Tuner 3.