GSM SMS Alarm Messenger
Pro X (Premium)
19
1
st
Relay Control
11.8)
Alarm Input Level & Alert Setup
Command: PWD:
XXXX
,ALMLEVEL
R:X,YY,ZZZZ,NNN
%
XXXX Password
R
Alarm Channel Number
X 0
means
“Disabled”
1 means “Close” triggered alarm
2 means “Open” triggered alarm
3 means both “Close” or “Open” triggered alarm
YY
00 means alarm not report to Control Centre
10 means alarm report to Control Centre 1
01 means alarm report to Control Centre 2
11 means alarm report to Control Centre 1 and 2
ZZZZ
Selection of alarm phone dial and alarm SMS
0 means no alarm report
1 means “SMS” only
2 means “phone dial” only
3 means “SMS” first, and then “phone dial”
Z Z Z Z
NNN Relay
Output
Control
0 means no relay output control
1 means relay output triggered by alarm
N N N
Note on PC Setup Software:
Alarm Default Level
SMS Command Value (X)
PC Setup Display
0 means “Disabled”
NA
1 means “Close” triggered alarm
NP
2 means “Open” triggered alarm
NC
3 means both “Close” or “Open” triggered alarm
SC
1
st
phone number
2
nd
phone number
3
rd
phone number
4
th
phone number
2
nd
Relay Control
3
rd
Relay Control