11.12)
Relay Output Control
Command: PWD:
XXXX
,COUT
N
:
Y
%
XXXX Password
N
Relay Output Channel (1 ~ 3)
Y
1
Turn On (Close) the output
0
Turn Off (Open) the output
Relay Output is Normally Open by default. The default can be changed by the jumper on
the board.
y
Command “COUTN:1” is NOT valid when the relay output is triggered by alarm.
Reply message will be “ST:XXX” in this case.
y
In the above case, command “COUTN:0” is used to reset the relay output after the
alarm is triggered.
11.13)
Relay Output Delay Time
Command: PWD:
XXXX
,OUT
N
DLAY:
YYYY
%
XXXX Password
N
Relay Output Channel (1 ~ 3)
YYYYY
0000 – 9999 seconds
0000
Turn On or Off the output (default)
0005
Turn On the output for 5 seconds, and then Off again
Turn Off the output for 5 seconds, and then On again
Relay output delay time is good for controlling the device e.g. electric door lock/unlock.
Only a time lapse on/off is necessary.
11.14)
Operating Voltage Low Level Alarm SMS
When the power supply voltage level is below the min. level at 5.34VDC, alert SMS is
sent.
Date:
2007-06-15
Time:
13:25
ST:001;TM:200706151325;V:5.34#