GSM SMS Alarm Messenger
Pro X (Premium)
20
Example 1:
PWD:1234,ALMLEVEL2:1,01,1030,010%
Password: 1234
Alarm Channel 2: Once input is closed, alarm is triggered.
Control Centre 2 will be reported by SMS.
Phone Number 1-
SMS alert
Phone Number 2-
no report
Phone Number 3-
SMS alert , then phone dial
Phone Number 4-
no report
Relay Output 1 -
no control
Relay Output 2 -
triggered “CLOSE” by alarm
Relay Output 3 -
no control
Example 2:
PWD:1234,ALMLEVEL1:1,11,1230,
1
00%
Password: 1234
Alarm Channel 1: Once input is closed, alarm is triggered.
Control Centre 1 & 2 will be reported by SMS.
Phone Number 1-
SMS alert
Phone Number 2-
alarm phone dial
Phone Number 3-
SMS alert , then phone dial
Phone Number 4-
no report
Relay
Output
1
-
triggered “CLOSE” by alarm
Relay Output 2 -
no control
Relay Output 3 -
no control
Example 3:
How to make the “Relay Output 3” triggered by alarm channels 2 & 5?
Once set, the relay output 3 will no longer be controlled by command 10 “COUT3:1’.
Method 1
Enable the control 3 triggered by alarm channels 2 & 5
PWD:1234,ALMLEVEL
2
:1,11,1111,00
1
%
PWD:1234,ALMLEVEL
5
:1,11,1111,00
1
%
Method 3
Programmed by PC Software “SMDPro” via RS232
Note:
Microphone should be connected if “alarm phone dial” is selected.