background image

Page 4 of 4

Model:

REC - 1240

REC - 1260

Unit 2, 110 Station Road, Seven Hills ,NSW,  2147, Australia

24V to 12V 

Reducer / Equalizer / Charger

Operating Instructions

Please read these instructions before use

REC-R2

REC - 1240

REC – 1260

Input Voltage [ VDC ]

23VDC to 30VDC

Charger Mode

Output Voltage (Absorption/Float) [ VDC ]

13.5VDC  ± 1%

Output Voltage (Bulk) [ VDC ]

14.5VDC  ± 1%

Equalizer Mode

Output Voltage

½ Input Voltage ± 3%

Reducer Mode

Output Voltage

13.5VDC ± 1%

Greater than 85%

Bulk Charge Current [A]

40A

60A

Stand – By Current [mADC]

20mA

Features

Short Circuit Protection

Battery Reversal Protection

Over Voltage and Thermal Protection

Dimensions [ L x W x H] 

313mm x 175mm x 65mm

313mm x 175mm x 65mm

Weight 

2.5Kg

2.6Kg

Equalizer Mode -

Output LED: 

This LED indicates the power output of the Equalizer

A)

 Current output less than 1amp. This would indicate that the battery is equalized

B)

 or the unit has just entered current limit. A solid output LED indicates that the unit is operating with in the nominal range.

The LED will remain off when either:-
A) 

The Ignition Wire is disconnected.

B)

 Output Over Voltage or Thermal Protection

Warranty Conditions:

 Our products come with guarantees that cannot be excluded under the Australian Consumer Law.

The customer is entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage.
The customer is also entitled to have the products repaired or replaced if the products fail to be of acceptable quality and the failure does not 
amount to a major failure.
GSL Electronics (GSL) warrants that its products will, under normal use and service, be free of defects in material and workmanship for a 
period of two (2) years from the date of the original purchase by the customer as marked on the customer’s original invoice. Please refer to our 
website for full warranty and return information which can be found at http://www.gsl.com.au/faq.html

Summary of Contents for REC-1240

Page 1: ...d 3 Choose a position with good ventilation where air can pass freely around the unit 4 Ensure the unit is protected from water spray and other sources of contamination e g oil grease and dust 5 Ensure that unit is installed away from any flammable fumes liquids or materials 6 During charging process do not use a naked flame near a battery due to gases emitted from the battery which may ignite and...

Page 2: ...g Modes Located on the rear of the unit the opposite end to the output terminals The switch is used for adjusting the mode of opperation Caution This should only be done before installing the unit Do not change modes with out reconfiguring the wiring as per the diagrams below Fig 1 for Charger Fig 2 for Reducer and Fig 3 for Equalizer Fig 2 Typical Installation Diagram for Reducer Mode Input Input...

Page 3: ...tes that the charger is in a charge state A solid output LED indicates a charged battery and that the charger is in float mode The LED will remain off when either A The charger s battery sensing technology does not sense a battery on the output B The battery has been detected to be faulty Check 12V with a meter to establish if the battery is with in the range of 7V to 13V C The Ignition Wire is di...

Page 4: ...B or the unit has just entered current limit A solid output LED indicates that the unit is operating with in the nominal range The LED will remain off when either A The Ignition Wire is disconnected B Output Over Voltage or Thermal Protection Warranty Conditions Our products come with guarantees that cannot be excluded under the Australian Consumer Law The customer is entitled to a replacement or ...

Reviews: