Page 3 of 4
Model:
REC - 1240
REC - 1260
Unit 2, 110 Station Road, Seven Hills ,NSW, 2147, Australia
24V to 12V
Reducer / Equalizer / Charger
Operating Instructions
Please read these instructions before use
REC-R2
LED Indicators:
Your new charger is fitted with a microprocessor which evaluates the state of charge and other features and
displays them via two LED’s.
Charger Mode
-
Input LED:
Nominal operation is indicated by the Input LED remaining solid.
Flashing Input LED indicates that input is below 25V. If the input voltage drops below 22V charger will switch off.
When the voltage returns to above 23V the unit will return to normal operation.
Output LED:
This LED indicates the charge state of the battery charger
When the LED is flashing this indicates that the charger is in a charge state.
A solid output LED indicates a charged battery and that the charger is in float mode.
The LED will remain off when either:-
A)
The charger’s battery sensing technology does not sense a battery on the output.
B)
The battery has been detected to be faulty. Check 12V with a meter to establish if the battery is
with in the range of 7V to 13V.
C)
The Ignition Wire is disconnected.
D)
Output Over Voltage or Thermal Protection
Fig 3. Typical Installation for Equalizer
Reducer Mode
-
Output LED:
This LED indicates the power output of the Reducer.
When the LED is flashing this indicates that the Reducer either:-
A)
Current output less than 1 Amp
B)
Or the unit has just entered current limit
A solid output LED indicates that the unit is operating with in the nominal range.
The LED will remain off when either:
A)
The Ignition Wire is disconnected
B)
Output Over Voltage or Thermal Protection
Input
Output
Ground
Control