background image

Instructions for use Hawker Lifetech

®

 Modular

ENGLISH

SafEty INStructIoNS

 aIM of tHIS MaNuaL

This manual  is designed for use by any skilled worker wishing 

to use Hawker Lifetech

®

 Modular battery chargers for rechar-

ging lead/acid vented, (with or without electrolyte mixing), 

valve regulated AGM and gel batteries.

This manual provides details of:

•  The chargers’ functions.

•  Any adjustments required and how to use the chargers.

When producing this manual, EnerSys

®

 has aimed to provide 

its information in as simple and precise a manner as possible 

but cannot assume any responsibility for any misinterpreta-

tion.  The  owner  of  the  equipment  is  required  to  retain  this 

manual  throughout  the  equipment’s  life  and  to  pass  it  on  

to any purchaser in the event of its resale.

The manufacturer covers the guarantee in accordance with 

the local regulations (contact local sales organization).

Recommended use

This manual should be read through carefully before using 

the  equipment  and  also  read  by  anyone  likely  to  use  the 

equipment. 

The equipment:

•   Presents no obstacles to the free circulation of air through 

the air inlet and outlet but, nevertheless, should be cleaned 

of dust every six months by a qualified person.

•   Must  be  used  in  conformance  with  its  indicated  level  of 

protection and never come into contact with water.

•   Must  be  used  within  the  temperature  limits  stated  in  the 

technical characteristics.

•   Must not be installed on surfaces subject to vibration (near 

to compressors, engines, motors).

•   Must be installed so that the gases from the battery being 

charged, do not get sucked into the charger by its fan.

This appliance is not intended for use by persons (including 

children) with reduced physical and mental capacities, who 

are not experienced in their use, unless instructed to do so by 

a person responsible for their safety.

Operator safety

Take  all  necessary  precautions  when  the  equipment  will  

be used in areas where there is the possible risk of an 

 

accident occurring. Ensure appropriate ventilation accor-

ding to standard EN 62485-3 to allow any gases released to 

escape. Never disconnect the battery while it is being charged.

 ELEctrIcaL SafEty

The prevailing safety regulations must be observed. The sys-

tem protection installed on the power supply to the charger 

must  conform  to  the  charger’s  electrical  characteristics.  The 

installation of a suitable circuit breaker is recommended. It is 

imperative to ensure that when fuses are being replaced only 

fuses  of  the  specified  type  and  of  the  correct  are  used.  It  is 

strictly forbidden to use inappropriate fuses or to short-circuit 

the fuse holders. This equipment conforms to Class 1 safety 

standards, which means that the appliance must be earthed 

and requires to be powered from an earthed supply.

Never open the equipment: High voltage could be still present 

even turning off the charger.

Any  adjustment,  maintenance  or  repairs  to  the  equipment 

while it is open must only be carried out by an appropriately 

skilled person who is aware of the risks involved.

Contact one of the company’s trained technicians if any prob-

lem is encountered when putting the charger into operation.

This equipment has been designed for indoor use. It is only 

designed to recharge lead/acid batteries on industrial premises.

When the equipment becomes obsolete, the casings and the 

other internal components can be disposed of by specialist 

companies. Local legislation takes precedence over any inst-

ructions in this document and must be scrupulously observed 

(WEEE 2002/96 EC).

EnerSys reserves the right to make any improvements and/or 

modifications to the product described in this manual at any 

time and without prior notice and is not obliged under any  

circumstances whatsoever to update the contents of this 

 

manual nor the equipment concerned.

The equipment’s production number must be supplied when 

requiring a service.

If the charger is to be stored before its use, it must be 

 

kept carefully sealed in its original packaging. It must be 

stored in a clean and dry location at a moderate tempera-

ture  (-20°C  to  +40°C).  Equipment  stored  at  a  temperature  of 

less  than  15°C  must  be  brought  progressively  to  operating 

temperature (over a period of 24 hours) to avoid any risk of  

condensation causing electrical faults (particularly short-

circuits).

 Eu DEcLaratIoN

EnerSys hereby declares that the chargers in the 

Lifetech Modular range covered by this declaration 

conform to the descriptions laid down in:

•  European Directive 2014/35/EU:

  Low Voltage Directive

  European Standard:

  EN60950-1: 2006+A11:2009+A12:2011+A1:2010+ A2:2013

•  European Directive 2014/30/EU:

  Electromagnetic Compatibility

  European Standards:

  -  EN61000-6-2: 2006

  -  EN61000-6-4: 2007+A1:2011

•  European Directive 2011/65/EU:

 ROHS

•  European Directive 2013/35/EU:

  Electromagnetic fields

  European Standards:

  -  EN62311: Oct 2008

Note: DC cables of the charger emit low power magnetic fields 

in their surroundings (<5cm). Even if emissions are below 

the standard limits, people bearing medical implants should 

avoid operating close to the charger during recharge.

Summary of Contents for Lifetech

Page 1: ...hat when fuses are being replaced only fuses of the specified type and of the correct are used It is strictly forbidden to use inappropriate fuses or to short circuit the fuse holders This equipment conforms to Class 1 safety standards which means that the appliance must be earthed and requires to be powered from an earthed supply Never open the equipment High voltage could be still present even t...

Page 2: ...esulphation equalizing and refreshing charges are also integrated Front Panel Ref Button LED Function Function 1 Start Stop button Start Stop charge Cancel value press during 3s select of active menu 2 Greed LED Battery available 3 Yellow LED Battery in charge 4 Red LED Fault 5 Blue LED AC supply ON light AC supply OFF AC missing 6 Arrows Navigation buttons Return to top of list press for 2 sec 7 ...

Page 3: ...ating Completion of charging 1 The LCD screen will give you the message of availability AVAIL The battery is charged and ready to use 2 STOP the charge and disconnect the battery To stop the charge press the Stop Start button Never disconnect the battery during charge without stopping the charging process This could lead to dangerous sparks or to charger damage 3 Completion of charging with equali...

Page 4: ...ective cells high tempe rature water level DF7 Pneumatic mixing air circuit fault the red light flashes Check the air circuit pump tubing TH Thermal fault resulting in interruption of charging Check that the fan s is are working correctly and or that the ambient temperature is not too high or whether there is poor natural ventilation to the charger MOD TH Alternating with charge parameters one or ...

Reviews: