The auxiliary battery is charged from the vehicle system when the engine is running. This is detected via
the ignition wire.
The unit will automatically select Boost (12V) or Reducer (24V) mode depending on the vehicle’s voltage
levels.
When the vehicle is off and the charger is drawing power from the solar panels, it will automatically use
the solar regulator if the input is lower than 20W. Once the power increases to above 20W, to maximise
efficiency the charger will automatically switch into MPPT mode.
When the vehicle is not switched on and there is no daylight is available, the unit reverts to standby mode
(<0.03A).