4. Assembly
34
PNEG-1333
Turkey Poult Feeder System
Shocker Wire Installation (Continued)
7. Use two (2) AZUMA nuts and bolts to connect a jumper wire from last section of shocker wire to the
anti-roost guard as shown in
. This wire is in close proximity to metal parts so an insulated,
12 gauge, single strand wire must be used.
Figure 4AS
8. After the shocker wire has been installed to the entire feed line, connect the circuit between the
shocker wire and shocker electrical control unit (See wiring instructions
included with the
shocker electrical control unit.)
NOTE:
Make certain that the jumper wires do not come into contact with any metal parts (auger tube,
insulator brackets, etc.).