![GSi Agri-Alert 128 Touch Installation And Configuration Manual Download Page 93](http://html1.mh-extra.com/html/gsi/agri-alert-128-touch/agri-alert-128-touch_installation-and-configuration-manual_2275092093.webp)
15
Troubleshooting
The 28 volt auxiliary is
disconnected
Make sure the 28VDC does not exceed the circuit capacity.
Check the main sector to the AA128 Touch and wiring.
Check if the fuse F31 or F32 is not opened.
Use a voltmeter to check voltage at the AA128 Touch supply input terminals
(24Vdc minimum at J13 between VDC+ and VDC-).
If the problem persists, contact your dealer.
The 12 volt auxiliary is
disconnected
Make sure the load connected to the 12VDC output does not exceed the circuit
capacity.
Check the wiring of the 12VDC output.
Check if the fuse F29 or F30 is not opened.
If the problem persists, contact your dealer.
The SBI power is diconnected
Make sure the SBI power output and siren do not exceed the circuit capacity.
Check the main sector to the AA128 Touch and wiring.
Check if the fuse F27 or F28 is not opened.
Use a voltmeter to check voltage at the AA128 Touch supply input terminals
(24Vdc minimum at J13 between VDC+ and VDC-).
If the problem persists, contact your dealer.
The siren output is
disconnected
Make sure the load connected to the siren output does not exceed the circuit
capacity.
Check the wiring of the siren output.
Check if the fuse F33 or F34 is not opened.
If the problem persists, contact your dealer.
The Low battery icon is dis-
played and electrical power is
functioning
Check the main sector to the AA128 Touch and wiring.
Use a voltmeter to check voltage at the AA128 Touch supply input terminals
(24Vdc minimum at J13 between VDC+ and VDC-).
Check the battery wiring.
Use a voltmeter to check voltage at the battery terminal (battery at full load:
between 12 and 13 V).
If the problem persists, contact your dealer.
The recharge is suspended
That is not a problem. The system automatically stops charging the battery
when the battery's temperature gets too high.
The No battery icon is displayed
Make sure a battery is connected to the controller .
895–00677
Agri Alert 128 Touch
93
Summary of Contents for Agri-Alert 128 Touch
Page 14: ...NOTES 14 895 00677 Agri Alert 128 Touch...
Page 20: ...NOTES 20 895 00677 Agri Alert 128 Touch...
Page 30: ...NOTES 30 895 00677 Agri Alert 128 Touch...
Page 38: ...NOTES 38 895 00677 Agri Alert 128 Touch...
Page 44: ...NOTES 44 895 00677 Agri Alert 128 Touch...
Page 64: ...Chapter 9 Configuring a 0 5 Volt Zone Type 64 895 00677 Agri Alert 128 Touch...
Page 66: ...NOTES 66 895 00677 Agri Alert 128 Touch...
Page 82: ...NOTES 82 895 00677 Agri Alert 128 Touch...
Page 88: ...NOTES 88 895 00677 Agri Alert 128 Touch...
Page 92: ...NOTES 92 895 00677 Agri Alert 128 Touch...
Page 96: ...NOTES 96 895 00677 Agri Alert 128 Touch...
Page 100: ...NOTES 100 895 00677 Agri Alert 128 Touch...
Page 102: ...NOTES 102 895 00677 Agri Alert 128 Touch...
Page 106: ...NOTES 106 895 00677 Agri Alert 128 Touch...
Page 107: ...F Wiring Diagram with Terminals 895 00677 Agri Alert 128 Touch 107...
Page 110: ...NOTES 110 895 00677 Agri Alert 128 Touch...
Page 118: ......